文献速递乳房整形与再造美容整形

圆型与Ergonomix假体乳房手术美学效果与长期随访比较

Ergonomix versus Round Implants: A Comprehensive Evaluation of Aesthetic Outcomes and Long-Term Follow-Up in Breast Surgery.
PubMed 文献 · Plast Reconstr Surg · 2025-10-14

共662次评估显示,圆型假体正确识别率为68.3%,Ergonomix为51.9%;站立位Ergonomix识别率从47.8%显著提升至70.8%(P=0.041)。结论认为Ergonomix假体兼具圆型与解剖型优势,随时间在直立位呈现更自然外观。

要点

  • 盲法评估中圆型假体识别率68.3%,Ergonomix仅51.9%。
  • 站立位Ergonomix识别率从47.8%升至70.8%(P=0.041)。
  • Ergonomix组乳头至乳房下皱襞距离增加稍多但无统计学意义。

核心结论

  • Ergonomix假体结合传统圆型与解剖型设计优势,呈现重力响应性动态行为,在直立位随时间更显自然。
  • 长期随访中Ergonomix识别准确率提升,提示其长期性能可能被低估,需延长随访评估。

研究设计与样本

  • 采用标准化手术技术,术后6和18个月由盲法独立评估者分析形态、轮廓与对称性。
  • 统计方法包括Mann-Whitney、Wilcoxon及评估者间信度检验,显著性设定P<0.05。

主要发现

  • 患者平均年龄24.5岁,术前乳房体积与假体尺寸相似。
  • 共662次评估,圆型假体正确识别率68.3%,Ergonomix正确识别率51.9%。
  • 站立位Ergonomix假体识别率从47.8%显著提升至70.8%(P=0.041)。
  • Ergonomix组乳头至乳房下皱襞距离增加稍多,但无统计学显著性。

临床怎么用

  • 对于追求自然动态外观的隆乳患者,Ergonomix假体在直立位随时间可能呈现更自然效果。
  • 术后评估应关注站立位形态变化,并延长随访以充分评估假体长期表现。

局限性

  • 随访至18个月,长期性能仍需更长时间评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breast implant shape influences final aesthetic outcomes, but direct comparisons remain limited. Anatomical implants offer natural results but have associated risks. Round implants provide fullness with fewer complications. This study assesses whether experienced surgeons can distinguish between Motiva round and Ergonomix implants postoperatively. METHODS: Twenty patients undergoing primary subfascial breast augmentation were randomly assigned to receive either Motiva round or Ergonomix implants. Standardized surgical techniques were applied, and postoperative evaluations occurred at 6 and 18 months, conducted by blinded independent assessors analyzing shape, contour, and symmetry. Statistical tests included Mann-Whitney, Wilcoxon, and interrater reliability, with significance set at P < 0.05. RESULTS: Patients had a mean age of 24.5 years, with similar preoperative breast volumes and implant sizes. A total of 662 evaluations showed that round implants were identified correctly at a rate of 68.3%. Ergonomix implants were identified correctly in 51.9% of cases. In the standing position, recognition of Ergonomix implants improved significantly from 47.8% to 70.8% ( P = 0.041). The nipple-to-inframammary fold distance increased slightly more in the Ergonomix group, without statistical significance. CONCLUSIONS: Ergonomix implants effectively combine the advantages of traditional round and anatomical designs, delivering a dynamic, gravity-responsive behavior that results in a more natural breast appearance, particularly in the upright position over time. The increased recognition accuracy suggests that their long-term performance may be underestimated, emphasizing the importance of extended follow-up to fully assess implant outcomes.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Graf RM, Ono MCC, de Paula DR, et al. Ergonomix versus Round Implants: A Comprehensive Evaluation of Aesthetic Outcomes and Long-Term Follow-Up in Breast Surgery. Plast Reconstr Surg. 2025. PMID: 41086305. doi:10.1097/PRS.0000000000012519

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。