烧伤住院患者骨骼肌A型超声评估的可行性、信度与临床效用
结果显示图像获取率69%、可分析率89%,总体评定者间ICC≥0.84、评定者内ICC≥0.95,但信度与临床效用依评定者而异,建议由同一评定者重复测量。
要点
- A型超声评估烧伤患者骨骼肌厚度可行,图像获取率69%、可分析率89%。
- 总体评定者间ICC≥0.84、评定者内ICC≥0.95,但配对间差异大。
- 信度与临床效用依评定者而异,建议固定同一评定者纵向评估。
核心结论
- A型超声评估烧伤患者骨骼肌可行,但信度与临床效用依评定者而异,推荐由同一评定者进行评估。
主要发现
- 图像在69%的计划 occasions 获取,89%的图像可分析。
- 总体评定者间ICC≥0.84(配对间0.63-0.99),评定者内ICC≥0.95(配对间0.45-0.99)。
- 总体评定者间SDC≤测量均值的33%(配对间3-52%),评定者内SDC≤20%(配对间3-48%)。
- 五名评定者均能以中至优信度测量腿部,但部分评定者测量手臂信度差。
关键数值与推荐
- 可行性:图像获取率69%,可分析率89%。
- 信度:总体评定者间ICC≥0.84,评定者内ICC≥0.95。
- 临床效用:总体评定者间SDC≤33%,评定者内SDC≤20%。
临床怎么用
- A型超声可用于烧伤患者骨骼肌监测,但应固定同一评定者以减少测量变异。
- 手臂测量信度可能较差,解读时需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Amplitude-mode (A-mode) ultrasonography is a promising technique to monitor loss and recovery of skeletal muscle in patients with burns. However, its clinimetric properties are unknown. Therefore, we determined its feasibility, interrater, and intrarater reliability, and clinical utility. METHODS: Skeletal muscle thickness of upper arms and legs was assessed longitudinally in hospitalized adult patients with ≥ 5 % total body surface area (TBSA) burns, by pairs of two out of five raters. Feasibility was evaluated by % successful assessments, reliability by intra-class correlation coefficients (ICCs), and clinical utility by smallest detectable change (SDC). RESULTS: Thirty-four patients participated (77 % male; mean age 48 ± 17 y, median TBSA burned 12 % [IQR 7-19]). Images were acquired on 69 % of planned occasions, and 89 % of images could be analyzed. Overall interrater ICCs were ≥ 0.84 (for pairs: 0.63-0.99) and intrarater ICCs were ≥ 0.95 (for pairs: 0.45-0.99). The overall interrater SDC was ≤ 33 % of the measured mean (for pairs: 3-52 %), while intrarater SDC was ≤ 20 % (for pairs: 3-48 %). All five raters could measure legs with moderate to excellent reliability, whereas for arms some demonstrated poor reliability. CONCLUSION: A-mode ultrasonography assessment of skeletal muscle in patients with burns is feasible. However, reliability and clinical utility are rater-dependent; therefore we recommend assessments by the same rater.
引用
- Bosch FG, Jager-Wittenaar H, Wesseling-Keuning GC, et al. Feasibility, reliability, and clinical utility of skeletal muscle assessment with A-mode ultrasonography in hospitalized patients with burns. Burns. 2025. PMID: 40885106. doi:10.1016/j.burns.2025.107673
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。