手持无线激光散斑对比成像评估DIEP皮瓣灌注的初步研究

Assessing DIEP flap perfusion using handheld wireless laser speckle contrast imaging: A proof of principle study.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2025-05-06

该初步研究设计无线手持激光散斑对比成像设备,在15例患者20个DIEP皮瓣中于围手术期4个时间点及术后第1天测量4个Hartrampf分区灌注。单侧重建皮瓣显示分区灌注梯度,蒂夹闭时可检测灌注下降,设备通过异常灌注值识别2例皮瓣失败,但运动伪影校正仍需改进。

要点

  • 无线手持LSCI设备可检测DIEP皮瓣各分区灌注差异及蒂夹闭时灌注下降。
  • 设备通过异常灌注值识别2例皮瓣失败,但需运动伪影校正。
  • 尚需进一步研究确定该设备能否早期发现并发症。

核心结论

  • 该设备检测到皮瓣各分区灌注差异、蒂夹闭时灌注下降及失败皮瓣的异常灌注,可能对皮瓣监测有价值。

研究设计与样本

  • 病例系列研究,纳入15例患者共20个DIEP皮瓣,于围手术期4个特定时间点及术后第1天在4个Hartrampf分区测量灌注。

主要发现

  • 单侧重建中,游离皮瓣各分区呈现灌注梯度,I区灌注最高,IV区最低。
  • 单侧皮瓣从抬升到临时夹闭的测量中检测到灌注下降,双侧皮瓣中未检测到。
  • 设备通过测量异常灌注值检测到2例皮瓣失败。

临床怎么用

  • 该设备可能用于DIEP皮瓣监测,但需运动伪影校正以在患者呼吸、脉搏及操作者运动时可靠测量。

局限性

  • 需要运动伪影校正以在患者呼吸、脉搏及操作者运动引起的运动过程中可靠测量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In reconstructive surgery, adequate perfusion of flaps is essential for successful outcomes. Assessing normal flap perfusion and differentiating it from problematic perfusion is important and time-consuming. Laser speckle contrast imaging (LSCI), an optical technique for quantitative microcirculation assessment, can be used to non-invasively monitor flap perfusion. We designed a wireless handheld LSCI device and investigated its clinical feasibility in Deep Inferior Epigastric Perforator (DIEP) flap reconstruction surgery. METHODS: In a case series study with 15 patients and 20 DIEP flaps, perfusion was measured perioperatively across the 4 Hartrampf zones at 4 specific time points and on the first post-operative day. RESULTS: In unilateral reconstructions, the perfusion in dissected flaps showed a perfusion gradient across the zones, with the highest perfusion in zone I and lowest perfusion in zone IV. The decrease in perfusion between unilateral flap elevation and temporary occlusion measurements was detected in unilateral flaps, but not in bilateral flaps. The device could detect flap failure in 2 cases by measuring anomalous perfusion values. CONCLUSIONS: The results indicate that our device is potentially valuable for flap monitoring. It detected differences in perfusion throughout the flap zones, a decrease in perfusion when clamping the pedicle and anomalous perfusion in flaps that failed. Motion artefact correction is needed to measure reliably during motion caused by patient breathing, pulse and operator motion. Further studies are needed to determine whether the wireless perfusion imager enables the early detection of complications, which could aid in prevention or prompt reintervention to salvage a flap.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Rook ARD, Chizari A, Knop T, et al. Assessing DIEP flap perfusion using handheld wireless laser speckle contrast imaging: A proof of principle study. J Plast Reconstr Aesthet Surg. 2025. PMID: 40532279. doi:10.1016/j.bjps.2025.04.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。