文献速递显微修复重建创面修复

热成像与多普勒识别穿支血管的比较

A Comparison of Thermal Imaging to Doppler in Perforator Vessel Identification.
PubMed 文献 · Ann Plast Surg · 2025-01-01

BACKGROUND: Precise identification of perforators is necessary for perforator flap planning and success. Various localizing modalities are currently utilized. Doppler is the perioperative modality of choice but can be time consuming and operator dependent.…

要点

  • 热成像初次识别穿支平均耗时1.06分钟,多普勒为3.57分钟(P < 0.001)。
  • 42个ALT皮瓣区域初次扫描多普勒识别143个穿支,热成像识别142个,一致率72.5%。
  • 39个不一致热成像热点经多普勒复查后29个确认信号,总体一致率93%。

核心结论

  • 热成像作为皮瓣规划辅助工具,可更快速扫描皮肤区域并揭示手持多普勒单独遗漏的穿支。

主要发现

  • 初次扫描热成像平均耗时1.06分钟,多普勒平均耗时3.57分钟(P < 0.001)。
  • 42个ALT皮瓣区域初次扫描多普勒识别143个穿支,热成像识别142个,初次一致率72.5%。
  • 39个初次不一致的热成像热点经多普勒复查后29个确认信号,总体一致率93%。

关键数值与推荐

  • 穿支标记在两种模态间对齐在1 cm内判定为一致。
  • 初次扫描记录识别穿支时间、数量、初次一致率及多普勒复查后总体一致率。

临床怎么用

  • 热成像可作为皮瓣规划的辅助手段,更快速扫描皮肤区域并揭示手持多普勒单独遗漏的穿支。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Precise identification of perforators is necessary for perforator flap planning and success. Various localizing modalities are currently utilized. Doppler is the perioperative modality of choice but can be time consuming and operator dependent. Thermal imaging is an affordable, easy-to-use technology that produces a color image based on surface temperature. This study aims to compare the proficiency and speed of thermal imaging to Doppler in perforator identification. METHODS: Twenty-one participants (42 thighs) were studied. A circle with a 5-cm radius at the midpoint between theanterior superior iliac spine and lateral patella was marked. Two investigators independently utilized either Doppler or thermal imaging to identify perforators within the marked territory. Thermal hotspots were marked first with invisible UV ink to blind the other investigator, who then scanned the same territory with Doppler. Concordance was determined if respective perforator markings between modalities aligned within 1 cm. After first pass, any nonconcordant thermal hotspots were rescanned with Doppler. Initial time taken and number of perforators found at first pass, first-pass concordance, and overall concordance after Doppler rescan were recorded. RESULTS: At first pass, average time to identify perforators using Doppler was 3.57 minutes and 1.06 minutes using thermal imaging (P < 0.001). Among 42 ALT flap territories, 143 perforators were identified by Doppler and 142 by thermal imaging on initial scan, from which there was 72.5% initial concordance between modalities. Of the 39 nonconcordant thermal hotspots on first pass, an additional 29 then had a Doppler signal confirmed on rescan, resulting in an overall concordance of 93%. CONCLUSIONS: When used as an adjunct for flap planning, thermal imaging allows more efficient perforator identification by more quickly scanning a cutaneous territory and unmasking perforators missed by handheld Doppler alone.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Potturi N, Carpentier SH, Feldmann ME, et al. A Comparison of Thermal Imaging to Doppler in Perforator Vessel Identification. Ann Plast Surg. 2025. PMID: 40459462. doi:10.1097/SAP.0000000000004390