低剂量氯己定冲洗预防组织扩张器乳房再造术中污染
单术者回顾性研究纳入53例患者94侧无引流胸肌前组织扩张器乳房再造,42侧术中用低剂量氯己定葡萄糖酸盐冲洗并浸泡扩张器,52侧未用。冲洗组术中培养阳性0侧 vs 未冲洗组5侧(0% vs 9.6%,P=0.039),术后感染率两组相似(11.9% vs 9.6%,P>0.05)。作者认为低剂量氯己定可减少术中污染。
要点
- 低剂量氯己定冲洗组术中培养阳性0侧,未冲洗组5侧(0% vs 9.6%,P=0.039)。
- 术后乳房感染率两组相似:冲洗组11.9% vs 未冲洗组9.6%(P>0.05)。
- 未冲洗组检出细菌为凝固酶阴性葡萄球菌1侧和痤疮 Cutibacterium 4侧。
核心结论
- 低剂量氯己定冲洗可减少组织扩张器乳房再造术中的细菌污染,但两组临床感染率仍相似,需更长随访和更大样本进一步了解其在预防感染及包膜挛缩中的作用。
研究设计与样本
- 单术者回顾性研究,纳入53例患者94侧胸肌前无引流组织扩张器乳房再造,其中42侧用低剂量氯己定冲洗,52侧未用。
主要发现
- 冲洗组与未冲洗组年龄分别为52.4岁 vs 47.2岁、体质指数分别为23.3 kg/m2 vs 23.2 kg/m2(P>0.05)。
- 术中培养阳性:冲洗组0侧 vs 未冲洗组5侧(0% vs 9.6%,P=0.039)。
- 未冲洗组检出细菌:凝固酶阴性葡萄球菌1侧、痤疮 Cutibacterium 4侧。
- 术后乳房感染:冲洗组5侧 vs 未冲洗组5侧(11.9% vs 9.6%,P>0.05)。
临床怎么用
- 作者认为低剂量氯己定冲洗可减少术中污染,为维持或改善乳房再造手术室无菌状态提供潜在新选择。
局限性
- 原文指出需更长随访时间和更大样本量以进一步了解低剂量氯己定在预防感染及包膜挛缩中的作用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There are many intraoperative techniques and washes that are used to prevent bacterial contamination during breast reconstruction. Low-dose chlorhexidine gluconate (CHG) is a low-pressure irrigation that offers broad spectrum activity against microorganisms. Its use has been shown to decrease bacterial load in various implants. The aim of the study was to evaluate the ability of low-dose CHG irrigation in decreasing intraoperative bacterial detection and postoperative infections during drainless tissue expander-based breast reconstruction. METHODS: This is a single surgeon study including a retrospective review of patients with prepectoral drainless TE-based breast reconstructions. In breasts with CHG, breast pockets were irrigated with CHG immediately before TE placement. The TE was also soaked with CHG prior to placement. Cultures were taken from the aspiration port from the TE at the final step after closing. RESULTS: The study included 94 breasts from 53 patients: 52 breasts without CHG irrigation and 42 breasts with CHG irrigation. Patients with and without CHG irrigation were comparable in age and body mass index (47.2 years vs 52.4 years and 23.2 kg/m2 vs 23.3 kg/m2, P > 0.05). In breasts without CHG irrigation, 5 breasts had positive intraoperative cultures while zero breasts with CHG irrigation had positive cultures (9.6% vs 0%, P = 0.039). Bacteria detected in breasts without CHG irrigation included coagulase-negative Staphylococcus in 1 breast and Cutibacterium acnes in 4 breasts. Postoperative breast infection rate was similar between groups with 5 breast infections in both cohorts (9.6% vs 11.9%, P > 0.05). CONCLUSIONS: This was a pilot study comparing intraoperative culture results and postoperative infections between breasts treated with an additional low-dose CHG wash and those that did not during immediate TE-based breast reconstruction. This study provided evidence that low-dose CHG can reduce intraoperative contamination, offering objective data and insights into a potential new option to maintain, or even improve, sterility in the operating room during breast reconstruction. Although clinical infection rates remained similar between the two groups, longer follow-up time and larger sample size will provide further understanding of the role of low-dose CHG in preventing infection as well as capsular contracture.
引用
- Vaeth AM, Huang H, Kochheiser M, et al. The Use of Low-Dose Chlorhexidine Gluconate Irrigation in Preventing Intraoperative Contamination in Tissue Expander-Based Breast Reconstruction. Ann Plast Surg. 2025. PMID: 40167083. doi:10.1097/SAP.0000000000004268
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。