文献速递乳房整形与再造显微修复重建

肿瘤整形全机器人辅助入路:机器人手术整合于乳房切除与DIEP皮瓣重建

Oncoplastic Entirely Robot-Assisted Approach: Incorporating Robotic Surgery in Both Mastectomy and DIEP Flap Reconstruction.
PubMed 文献 · Plast Reconstr Surg · 2025-04-21

该回顾性病例系列纳入14例单侧乳腺癌患者,首次采用肿瘤整形全机器人辅助(OPERA)入路行机器人辅助乳房切除与机器人辅助游离DIEP皮瓣切取重建。乳房切除范围155至647克,切取皮瓣310至1213克,皮瓣均移植成功,随访19.1±15.6个月未见局部复发、远处转移或晚期供区并发症。作者认为OPERA入路在合适适应证患者中具有可行性。

要点

  • 14例单侧乳腺癌患者接受机器人辅助乳房切除与机器人辅助游离DIEP皮瓣切取。
  • 皮瓣重量310至1213克,所有皮瓣移植成功。
  • 随访19.1±15.6个月,未见局部复发、远处转移或晚期供区并发症。

核心结论

  • 作者认为OPERA入路在具有合适适应证的患者中已展示出可行性。

研究设计与样本

  • 回顾性病历审查纳入14例接受机器人辅助乳房切除与机器人辅助游离DIEP皮瓣切取重建的单侧乳腺癌患者,并回顾患者人口学特征及乳房切除与皮瓣特征。

主要发现

  • 共施行11例保留乳头乳房切除术、1例保留乳晕乳房切除术和2例保留皮肤乳房切除术,乳腺癌分期从导管原位癌至T3N2aM0。
  • 乳房切除标本大小为155至647克,平均376.9克,未发生乳房切除相关并发症。
  • 在机械臂辅助下分离18条腹壁下动静脉蒂,前鞘切口长度为2.6±0.9厘米,切取血管蒂平均长度10.3±2.2厘米。
  • 切取皮瓣大小为310至1213克(平均659.3±298.1克),所有皮瓣均移植成功。
  • 随访19.1±15.6个月,无患者出现局部复发、远处转移或晚期供区并发症。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breast cancer surgery involves a minimally invasive approach with the assistance of robotic technology. Robots can be used for harvesting free deep inferior epigastric artery perforator (DIEP) flaps for breast reconstruction to minimize donor-site morbidity. For the first time, the authors' team applied robot-assisted surgery using the oncoplastic entirely robot-assisted (OPERA) approach for both mastectomy and free DIEP flap harvesting. METHODS: A retrospective chart review identified 14 patients with unilateral breast cancer who underwent robot-assisted mastectomy and robot-assisted free DIEP flap harvesting for breast reconstruction. Patient demographics and mastectomy and flap characteristics were reviewed. RESULTS: Eleven nipple-sparing mastectomies, 1 areolar-sparing mastectomy, and 2 skin-sparing mastectomies were performed with breast cancer stage ranging from ductal carcinoma in situ to the more advanced stage of T3N2aM0. The size of the mastectomies ranged from 155 to 647 g, with an average of 376.9 g. No mastectomy-related complications occurred. Eighteen deep inferior artery and vein pedicles were dissected with the assistance of robotic arms, and the incision length of the anterior rectus sheath was 2.6 ± 0.9 cm. The average length of the harvested pedicle was 10.3 ± 2.2 cm. The harvested flap sizes ranged from 310 to 1213 g (average, 659.3 ± 298.1 g). All flaps were transferred successfully. With a follow-up period of 19.1 ± 15.6 months, none of the patients presented with local recurrence, distant metastasis, or late donor-site morbidities. CONCLUSION: The OPERA approach has demonstrated feasibility in patients with suitable indications.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Kuo WL, Wong AW, Tsai CY, et al. Oncoplastic Entirely Robot-Assisted Approach: Incorporating Robotic Surgery in Both Mastectomy and DIEP Flap Reconstruction. Plast Reconstr Surg. 2025. PMID: 40261832. doi:10.1097/PRS.0000000000012157

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。