文献速递瘢痕与激光创面修复显微修复重建

颈部扩张器包膜的生物力学与组织学转归

Biomechanical and histological outcomes of a cervical expander capsule.
PubMed 文献 · Burns · 2025-03-15

研究采集29例面部与颈部烧伤瘢痕患者的颈部扩张器深、浅层包膜,按扩张器取出后包膜体内留存时间分为四组,并与5名正常受试者皮肤对照,发现包膜厚度、杨氏模量、胶原含量、I/III型胶原比值及α-SMA表达与包膜层次和体内留存时间显著相关。

要点

  • 包膜厚度、杨氏模量、胶原含量、I/III型胶原比值及α-SMA表达与包膜层次及体内留存时间显著相关(p<0.05)。
  • 扩张器取出后包膜体内留存超过24个月时,其杨氏模量仍大于正常皮肤,限制颈部活动度。
  • 部分患者出现条索样包膜挛缩和颈部牵拉感,可能归因于深层扩张器包膜与颈阔肌融合。

核心结论

  • 颈部扩张器取出后包膜可在体内长期留存,影响颈部轮廓与活动度。

研究设计与样本

  • 收集29例因面部与颈部烧伤瘢痕行瘢痕切除与扩张皮瓣转移患者的颈部扩张器深、浅层包膜作为实验组,按扩张器取出后包膜体内留存时间分为四组;对照组为5名正常受试者皮肤;对各组包膜进行生物力学与组织学检测。

主要发现

  • 包膜厚度、杨氏模量、胶原含量、I/III型胶原比值及α-SMA表达水平与包膜层次及体内留存时间显著相关(p<0.05)。
  • 扩张器取出后包膜体内留存超过24个月时,包膜杨氏模量仍大于正常皮肤,限制颈部活动度。
  • 部分患者出现条索样包膜挛缩和颈部牵拉感,可能归因于深层扩张器包膜与颈阔肌融合。

关键数值与推荐

  • 包膜厚度、杨氏模量、胶原含量、I/III型胶原比值及α-SMA表达水平与包膜层次和体内留存时间显著相关(p<0.05)。
  • 扩张器取出后包膜体内留存超过24个月时,包膜杨氏模量仍大于正常皮肤。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: An expander capsule is a fibrous membrane that forms around a tissue expander. However, its outcome is still unclear. Here we investigated the biomechanical and histological outcomes of cervical capsules that were left in vivo after expanders were removed. METHODS: The deep and superficial capsules of 29 human cervical expanders were collected to serve as an experimental group. All 29 patients sustained facial and neck burn scars and underwent scar excision and expanded skin flap transfer. These capsules were divided into four groups based on the in vivo persistence time of the capsules following expander removal. The control group featured skin from five normal subjects. We investigated the biomechanics and histology of each group of capsules. RESULTS: Capsule thickness, Young's modulus, collagen content, type I/III collagen ratio and α-SMA expression level were significantly related to the layer and the persistence time of the capsule in vivo (p<0.05). Capsules persisted for more than 24 months following expander removal, the Young's modulus of the capsules remained greater than that of normal skin, limiting neck mobility. Moreover, some patients experience cord-like capsular contracture and a cervical pulling sensation, which may be attributable to the fusion of the deep expander capsules and platysma muscle. CONCLUSIONS: Following the removal of neck expanders, the capsules can persist in vivo for a long time, affecting cervical contours and mobility.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Li R, Cao Z, Yang J, et al. Biomechanical and histological outcomes of a cervical expander capsule. Burns. 2025. PMID: 40101612. doi:10.1016/j.burns.2025.107462

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。