入流时间作为吲哚菁绿血管造影评估即刻假体乳房重建中皮瓣灌注的指标
本研究回顾性纳入2021年6月至2022年12月间接受即刻假体乳房重建并术中行吲哚菁绿血管造影的203例患者(203侧乳房),评估入流时间预测乳房切除皮瓣全层坏死的价值。全层坏死发生率为16.3%,坏死组与无坏死组平均入流时间分别为104.6秒和47.6秒(P<0.001),最佳截断值70.5秒的敏感度82%、特异度84%、准确率83%,多因素分析示入流时间≥70.5秒为显著预测因子(OR 26.79,P<0.001)。
要点
- 全层坏死组平均入流时间104.6秒,无坏死组47.6秒(P<0.001)。
- 预测全层坏死的最佳入流时间截断值为70.5秒,敏感度82%、特异度84%、准确率83%。
- 入流时间≥70.5秒是全层坏死的显著预测因子(OR 26.79,P<0.001)。
核心结论
- 吲哚菁绿血管造影中的入流时间可能作为评估乳房切除皮瓣灌注的新指标。
研究设计与样本
- 回顾性审查2021年6月至2022年12月连续接受即刻假体乳房重建并术中行吲哚菁绿血管造影的患者,共203例患者203侧乳房;临时关闭切口后行120秒血管造影,记录入流时间(秒),主要结局为乳房切除皮瓣全层坏死。
主要发现
- 33例患者(16.3%)发生乳房切除皮瓣全层坏死。
- 坏死组平均入流时间104.6秒,无坏死组47.6秒(P<0.001)。
- 受试者工作特征曲线和精确率-召回率曲线分析得出最佳截断值70.5秒,敏感度82%、特异度84%、准确率83%。
- 多因素分析中,入流时间≥70.5秒是全层坏死的显著预测因子(OR 26.79,P<0.001)。
关键数值与推荐
- 最佳入流时间截断值为70.5秒,敏感度82%、特异度84%、准确率83%。
- 入流时间≥70.5秒预测全层坏死的OR为26.79(P<0.001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Rapid ingress is a hallmark of normal flap perfusion in indocyanine green (ICG) angiography. This study aimed to assess whether the ingress time in ICG angiography can be used to evaluate mastectomy skin flap (MSF) perfusion in immediate implant-based breast reconstruction (IBR). METHODS: Consecutive patients who underwent immediate IBR with intraoperative ICG angiography between June of 2021 and December of 2022 were retrospectively reviewed. ICG angiography was performed for 120 seconds after temporary skin closure. The ingress time, defined as the time (in seconds) for ICG to perfuse the entire MSF, including incision margins, was recorded. The primary outcome measured was the development of full-thickness MSF necrosis. A receiver operating characteristic curve and an F1 score based on the precision-recall curve analysis were used to determine the optimal ingress time cutoff value for predicting full-thickness necrosis of MSF. RESULTS: The study included 203 breasts from 203 patients. Full-thickness necrosis of MSF developed in 33 patients (16.3%). The mean ingress times in the necrosis and no-necrosis groups were 104.6 seconds and 47.6 seconds, respectively ( P < 0.001). In receiver operating characteristic and precision-recall curve analyses, the optimal cutoff value was 70.5 seconds, yielding a sensitivity of 82%, specificity of 84%, and accuracy of 83%. In multivariable analysis, an ingress time of 70.5 seconds or longer was a significant predictor of full-thickness necrosis of MSF (OR, 26.79; P < 0.001). CONCLUSION: An ingress time in ICG angiography may serve as a novel metric for evaluation of MSF perfusion. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.
引用
- Lee JK, Jeon BJ, Woo KJ, et al. Ingress Time as a Metric for Indocyanine Green Angiographic Evaluation of Skin Flap Perfusion in Immediate Implant-Based Reconstruction. Plast Reconstr Surg. 2025. PMID: 39946672. doi:10.1097/PRS.0000000000012034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。