周期性激光多普勒成像监测能否加深对股前外侧皮瓣灌注挑战的认识?一项5年回顾性分析
回顾性分析2018至2022年至少经历1次再探查的游离股前外侧皮瓣,采用固定时间激光多普勒扫描计算灌注指数(PI)。PI阈值<-0.62可识别皮瓣危象,敏感度80%、特异度70%;皮瓣存活组再探查后24小时内PI均值-0.61±0.03,高于阈值,且与部分坏死组(-0.86±0.02,P=0.034)差异有统计学意义。
要点
- 固定时间激光多普勒成像可提供无创、实时、可量化的皮瓣灌注监测。
- PI阈值<-0.62可识别游离股前外侧皮瓣危象,敏感度80%、特异度70%。
- 再探查后24小时内PI均值存活组-0.61±0.03 vs 部分坏死组-0.86±0.02,P=0.034。
核心结论
- 面对游离皮瓣移植后循环不确定时,激光多普勒成像可提供可靠、客观的术后监测方法。
- PI值≤-0.62可识别游离股前外侧皮瓣危象,该阈值可应用于再探查皮瓣,为评估疑似危象提供一种选择。
研究设计与样本
- 回顾性分析2018至2022年至少经历1次再探查手术的游离股前外侧皮瓣移植。
- 共纳入47个再探查的游离股前外侧皮瓣。
- 工作日每天进行1次固定时间激光多普勒扫描,获取皮瓣及邻近参考健康皮肤的流量均值,计算灌注指数(PI)为皮瓣与参考之间流量均值的百分比差异。
- 将再探查病例按年龄、性别和受区与未再探查病例进行倾向性评分匹配。
- 采用受试者工作特征曲线和约登指数确定定义皮瓣危象的PI截断值。
主要发现
- 10例在术后第1天危象前接受激光多普勒扫描的再探查病例与20例未再探查病例匹配。
- PI阈值<-0.62识别皮瓣危象的敏感度为80%、特异度为70%。
- 皮瓣存活组再探查后24小时内32例的PI均值为-0.61±0.03,高于PI阈值。
- 存活组与部分坏死组PI均值差异有统计学意义(-0.61±0.03 vs -0.86±0.02,P=0.034)。
关键数值与推荐
- PI阈值<-0.62识别皮瓣危象的敏感度为80%、特异度为70%。
- 再探查后24小时内PI均值:存活组-0.61±0.03(32例)vs 部分坏死组-0.86±0.02,P=0.034。
临床怎么用
- 作者认为,面对游离皮瓣移植后循环不确定时,激光多普勒成像可提供可靠、客观的术后监测方法。
- 作者认为,PI值≤-0.62可识别游离股前外侧皮瓣危象,该阈值可应用于再探查皮瓣,为评估疑似危象提供一种选择。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Postoperative monitoring after free flap transfer is challenging, and clinical observation alone remains subjective and unquantifiable. Furthermore, re-explored flaps often have a poor appearance, making it challenging for surgeons to decide whether further aggressive treatments are necessary. Laser Doppler (LD) imaging can provide noninvasive, real-time, and quantifiable monitoring for flap perfusion. This study aimed to utilize fixed-timing LD to assist in postoperative free flap monitoring, especially in re-explored flaps. MATERIAL AND METHODS: We retrospectively analyzed free anterolateral thigh (ALT) flap transfers with at least 1 re-exploration surgery from 2018 to 2022. Fixed-timing LD scans were conducted once a day on weekdays, and the flux mean of the flap and its adjacent reference healthy skin was obtained via an LD imager. The perfusion index (PI) was calculated as the percentage difference of flux mean between the flap and the reference. Timing of compromise, surgical findings and flap outcomes were recorded. Re-explored cases were matched with non-re-explored cases by propensity score matching for age, sex, and recipient site. Receiver operating characteristic curves and Youden's index were used to identify a PI cutoff value to define flap compromise. Post re-exploration outcomes were categorized into flap survival, partial necrosis, and failure. Post re-exploration LD data were analyzed with the Wilcoxon test. RESULTS: Forty-seven re-explored free ALT flaps were included. Ten re-explored cases with LD scans before compromise on postoperative day 1 were matched with 20 nonreopened cases. A PI threshold value < -0.62 could identify flap compromise with 80% sensitivity and 70% specificity. In the flap survival group, the mean PI mean was -0.61 ± 0.03 in 32 cases within 24 hours after re-exploration, which was higher than the PI threshold. A significant difference in PI mean was found between the survival and partial necrosis groups (-0.61 ± 0.03 vs -0.86 ± 0.02, P = 0.034). CONCLUSIONS: When facing uncertain circulation after free flap transfers, LD imaging can provide reliable and objective method for postoperative monitoring. A PI value ≤ -0.62 could identify free ALT flap compromise. This PI threshold value could be applied to re-explored flaps, providing an option to evaluate those in which compromise is suspected.