文献速递显微修复重建创面修复

术中躯体感觉诱发电位监测用于臂丛神经鞘瘤切除术的可行性:一项先导研究

Feasibility of Intraoperative Somatosensory Evoked Potential Monitoring for Resection of Brachial Plexus Schwannomas: A Pilot Study.
PubMed 文献 · Ann Plast Surg · 2025-01-01

本研究纳入2011年10月至2020年12月接受躯体感觉诱发电位(SSEP)引导显微手术的13例臂丛神经鞘瘤患者,描述SSEP辅助显微切除技术并评估手术结局。术后视觉模拟量表(VAS)疼痛评分较术前显著降低(P=0.005),术后未观察到神经血管损伤,术前神经功能缺损术后缓解或改善,术后上肢、肩、手功能残疾程度低。作者认为SSEP辅助精细手术技术可完全切除臂丛神经鞘瘤,尤其对下干受累患者有手术获益。

要点

  • 13例臂丛神经鞘瘤患者接受SSEP引导显微手术,术后VAS疼痛评分较术前显著降低(P=0.005)。
  • 术后未观察到神经血管损伤,术前神经功能缺损术后缓解或改善。
  • 术后上肢、肩、手功能残疾程度低;作者认为该技术尤其使下干受累患者获益。

核心结论

  • 作者认为,SSEP辅助精细手术技术可完全切除臂丛神经鞘瘤,对臂丛神经鞘瘤切除有手术获益,尤其在下干受累患者中。

研究设计与样本

  • 先导研究,纳入2011年10月至2020年12月接受SSEP引导显微手术的臂丛神经鞘瘤患者13例。

主要发现

  • 患者平均年龄50岁(范围29-64岁),肿瘤位于右侧6例、左侧6例、双侧1例。
  • 8例患者术前存在运动/感觉功能障碍。
  • 术后VAS疼痛评分较术前显著降低(P=0.005)。
  • 术后未观察到神经血管损伤;术前存在神经功能缺损的患者术后缺损缓解或改善。
  • 术后上肢、肩、手功能残疾程度低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The complex anatomical location of brachial plexus tumors is a formidable diagnostic and therapeutic challenge for surgeons. Intraoperative neurophysiologic monitoring enables the surgeon to proceed with more aggressive maneuvers for near total removal of the spinal cord tumor, such as somatosensory evoked potentials (SSEPs) monitoring. The present study aimed to describe the SSEP-assisted microsurgical excision technique and to evaluate the surgical outcomes of brachial plexus schwannomas. METHODS: Thirteen patients who underwent SSEP-guided microsurgery for brachial plexus schwannomas between October 2011 and December 2020 were included in our study. RESULTS: The mean age of the patients was 50 years (range, 29-64 years), with six tumors localized on the right, six on the left side and one on bilateral sides. Eight patients had preoperative motor/sensory dysfunction. Compared to preoperative Visual Analogue Scale (VAS) pain score, the postoperative VAS score significantly decreased in these patients (P = 0.005). No postoperative neurovascular injury was observed in the patients. Among patients who had a preoperative neurologic deficit, these preoperative neurologic deficits were relieved or improved after surgery. There was a low disability in the arm, shoulder, and hand after surgery. CONCLUSIONS: Brachial plexus schwannomas is able to completely excised by SSEP-assisted delicately surgical techniques, contributing to a surgical benefit for the excision of brachial plexus schwannomas, particularly in patients with lower trunk involvement.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Yao WT, Hsu HH, Liang ML, et al. Feasibility of Intraoperative Somatosensory Evoked Potential Monitoring for Resection of Brachial Plexus Schwannomas: A Pilot Study. Ann Plast Surg. 2025. PMID: 39996543. doi:10.1097/SAP.0000000000004204

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。