文献速递乳房整形与再造美容整形

皮下下极松解预防基底缩窄乳房双泡畸形:「加一」隆乳技术

Subcutaneous Lower Pole Release for Double Bubble Prevention in Constricted-Base Breasts: The "Plus One" Augmentation Technique.
PubMed 文献 · Aesthet Surg J · 2025-01-01

本研究为单术者回顾性分析,纳入46例2019至2021年接受「加一」技术隆乳的明确下皱襞缩窄患者,排除需乳房固定者。术后下极曲线96%为凸面,4%趋于变直,1例出现凹面提示双泡畸形(并发症率2%);BREAST-Q满意度评分术前43±2升至术后94±3。

要点

  • 「加一」技术在隆乳中引入第三剥离平面,用于预防或矫正双泡畸形。
  • 46例下皱襞缩窄患者术后96%下极曲线为凸面,双泡畸形并发症率为2%。
  • BREAST-Q满意度评分由术前43±2升至术后94±3。

核心结论

  • 「加一」方法结果稳定且令人满意,易于重复且并发症率低,可作为预防或矫正措施实施。

研究设计与样本

  • 本研究为单术者开展的回顾性分析,纳入46例下皱襞明确缩窄并接受「加一」技术隆乳的患者,手术时间为2019年至2021年。
  • 需行乳房固定的患者被排除。

主要发现

  • 术后下极曲线在96%的病例中为凸面,在4%的病例中下极曲线趋于变直。
  • 1例曲线在1个点处变为凹面,提示双泡畸形,双泡畸形并发症率为2%。
  • BREAST-Q量表平均术前满意度评分为43±2,术后满意度评分为94±3。

关键数值与推荐

  • 术后下极曲线凸面占96%,趋于变直占4%,出现凹面提示双泡畸形占1例(并发症率2%)。
  • BREAST-Q满意度评分术前43±2,术后94±3。
  • 随访时间为术后2周、6个月和12个月。

临床怎么用

  • 作者认为「加一」方法可作为预防或矫正双泡畸形的措施实施。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breasts with a broad base, constricted inframammary fold (IMF) and a short distance between the nipple and the IMF are predisposed to form a double bubble (DB) deformity. Most publications have focused on the correction of a DB rather than on its prevention and thorough analysis of the IMF. OBJECTIVES: The goal of this study was the introduction of a third dissection plane in breast augmentation for preventing or correcting DB deformities. METHODS: This study was a retrospective analysis conducted by a single surgeon, involving 46 patients with a well-defined constricted IMF who underwent breast augmentation with the "plus one" technique between 2019 and 2021. Patients who required mastopexy were excluded. All procedures were analyzed for lower pole curvature with visual and graphical photographic analysis. The lower pole breast contour was plotted as a graph for better comparison of outcomes. BREAST-Q surveys were conducted before and 3 months after surgery. Follow-ups were done at 2 weeks, 6 months, and 12 months after surgery. RESULTS: The curve of the postoperative lower pole was convex in 96% of the cases. In 4%, the curve tended to straighten out in the lower pole. In 1 case, the curve became concave at 1 point, indicating a DB deformity, making a DB complication rate of 2%. The mean preoperative satisfaction score was 43 ± 2, and the postoperative satisfaction score was 94 ± 3 on the BREAST-Q scale. CONCLUSIONS: The plus one method showed stable and satisfying results and was easily reproducible with a low complication rate. This can be performed as either a prophylactic or corrective measure.

来源:Aesthet Surg J,查看原文。版权归原作者所有。

引用

  1. Fertsch S, Wolter A, Rancati A, et al. Subcutaneous Lower Pole Release for Double Bubble Prevention in Constricted-Base Breasts: The "Plus One" Augmentation Technique. Aesthet Surg J. 2025. PMID: 39874280. doi:10.1093/asj/sjaf014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。