改良血管内支架用于大鼠股浅动脉微血管缝合
本研究将45条大鼠股浅动脉随机分为传统缝合组、改良血管内支架组和传统血管内支架组,每组15条,比较即刻及术后1、2、6周的通畅率、手术时间和超声血流动力学。改良支架组手术时间显著短于传统支架组,通畅率、超声血流动力学和组织学评价与传统缝合组效果相同。
要点
- 改良血管内支架组手术时间显著短于传统血管内支架组。
- 改良支架组通畅率、超声血流动力学和组织学评价与传统缝合组相同。
核心结论
- 改良血管内支架组手术时间显著短于传统血管内支架组。
- 改良血管内支架减少了传统血管内支架取出不便的问题。
- 改良血管内支架在通畅率、手术时间、超声血流动力学和组织学评价方面与传统缝合效果相同。
- 改良血管内支架可用于显微外科领域。
研究设计与样本
- 研究将45条大鼠股浅动脉随机分为传统缝合组、改良血管内支架组和传统血管内支架组,每组15条。
主要发现
- 平均手术时间传统缝合组为22.6分钟,改良血管内支架组为21.5分钟,传统血管内支架组为25.9分钟。
- 超声评价显示三组间峰值流速和狭窄率无显著差异。
- 组织病理学评价显示三组内皮细胞恢复过程相似,血管壁无损伤。
临床怎么用
- 原文结论认为改良血管内支架可用于显微外科领域。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Intravascular stent (IVaS) is sometimes used for suturing small vessels, but removing the stent after suturing is difficult. To overcome this problem, we developed an IVaS that integrates a stent and a manipulating string. This study aimed to investigate the usefulness of the modified IVaS (M-IVaS) by comparing it with conventional sutures (CS) and conventional IVaS (C-IVaS). METHODS: Forty-five superficial femoral arteries from rats were resected and sutured. The rats were randomly divided into the following 3 groups: CS, M-IVaS, and C-IVaS, with 15 rats per group. Patency rate, operating time, and ultrasonographic blood flow dynamics were examined immediately after suturing. Patency tests, ultrasonographic evaluations, and histological investigations were performed 1 week (n = 5), 2 weeks (n = 5), and 6 weeks (n = 5) after surgery. RESULTS: The 3 groups showed vessel patency in all cases immediately after suturing and at 1 week, 2 weeks, and 6 weeks after surgery. The mean operative time was 22.6 minutes for the CS group, 21.5 minutes for the M-IVaS group, and 25.9 minutes for the C-IVaS group. There were no significant differences in peak flow velocity and stenosis rate among the 3 groups as evaluated by ultrasonography. Histopathological evaluation revealed a similar recovery process of endothelial cells and no damage to the vascular wall. CONCLUSION: The surgical time using M-IVaS was significantly shorter compared to that using C-IVaS. The M-IVaS reduced the inconvenience of C-IVaS removal. M-IVaS showed the same effectiveness as did the CS in terms of patency rate, operating time, ultrasonographic blood flow dynamics, and histological evaluation. M-IVaS can be used in the field of microsurgery.
引用
- Maeda K, Suzuki T, Masugi Y, et al. Modified Intravascular Stent for Microvascular Suture in a Rat Superficial Femoral Artery. Ann Plast Surg. 2024. PMID: 39356089. doi:10.1097/SAP.0000000000004098
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。