下颌骨游离腓骨重建中计算机辅助设计与制造:长期结局比较
该研究纳入2012至2021年接受游离腓骨瓣下颌骨重建的215例患者(传统技术组79例,CAD/CAM组136例),比较两组短期与长期结局。CAD/CAM组平均手术时间缩短54分钟(P=0.014),早期伤口裂开率显著更低(P=0.037);排除术后30天内重大手术并发症患者后,CAD/CAM组硬件取出率更低(28.8% vs 13.9%,P=0.011)。
要点
- CAD/CAM组平均手术时间较传统组缩短54分钟(P=0.014)。
- CAD/CAM组早期伤口裂开率显著低于传统组(P=0.037)。
- 排除术后30天内重大并发症者后,CAD/CAM组硬件取出率13.9% vs 传统组28.8%(P=0.011)。
核心结论
- 术前CAD/CAM可能缩短手术时间,并使硬件更长久保留、因并发症导致的取出率更低。
研究设计与样本
- 回顾性比较研究,纳入2012至2021年接受游离腓骨瓣下颌骨重建的患者,传统技术组79例、CAD/CAM组136例。
- 比较患者人口学、病史、手术细节、并发症与重建结局;采用Kaplan-Meier法展示硬件维持的累积发生率。
- 证据等级:治疗性,III级。
主要发现
- CAD/CAM组患者更年轻(P=0.043)。
- CAD/CAM组平均手术时间较传统组缩短54分钟(P=0.014)。
- 两组总皮瓣丢失率与部分皮瓣丢失率相似。
- CAD/CAM组早期伤口裂开率显著更低(P=0.037)。
- 随访时间中位数(四分位距[IQR]):传统组931天(IQR,1854天) vs CAD/CAM组728天(IQR,841天),P=0.084。
临床怎么用
- 作者认为术前CAD/CAM可能缩短手术时间,并使硬件更长久保留、因并发症导致的取出率更低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Preoperative computer-aided design and computer-aided manufacturing (CAD/CAM) revolutionized head and neck reconstruction after extirpative surgery. However, studies performing head-to-head comparison to the conventional technique have limited long-term follow-up. The authors aimed to compare short and long-term outcomes between conventional and CAD/CAM approaches for mandibular reconstruction with free fibula flaps. METHODS: Patients undergoing free flap reconstruction from 2012 to 2021 were included. Data regarding patient demographics, medical history, surgical details, complications, and reconstructive outcomes were collected. Patients who had CAD/CAM were compared with the patients who underwent reconstruction with the conventional technique. The cumulative incidence of hardware maintenance was displayed using the Kaplan-Meier method. RESULTS: A total of 215 patients (conventional, n = 79; CAD/CAM, n = 136) were included. Both cohorts had similar demographics, but the CAD/CAM cohort was younger ( P = 0.043). The mean operative duration was 54 minutes shorter with the use of CAD/CAM ( P = 0.014). Total and partial flap loss rates were similar. Patients with CAD/CAM had significantly lower rates of early wound dehiscence ( P = 0.037). Median (interquartile range [IQR]) follow-up duration was similar (931 days [IQR, 1854 days] in conventional versus 728 days [IQR, 841 days] days in CAD/CAM; P = 0.084). After excluding patients with major surgical complications in the first 30 days, the CAD/CAM cohort had a lower hardware removal rate (28.8% versus 13.9%; P = 0.011). The significance persisted after including only the patients with more than 2 years of follow-up. CONCLUSION: The use of preoperative CAD/CAM may reduce operative duration, while allowing for longer maintenance of hardware with reduced removal rates because of complications. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.
引用
- Bengur FB, Humar P, Saadoun R, et al. Computer-Aided Design and Manufacturing in Free Fibula Reconstruction of the Mandible: Comparison of Long-Term Outcomes. Plast Reconstr Surg. 2024. PMID: 39436738. doi:10.1097/PRS.0000000000011701
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。