猪源黏膜下细胞外基质包裹尺神经在肘管翻修手术中的应用
回顾性队列研究评估猪源黏膜下细胞外基质(PECM)神经保护器作为持续性或复发性肘管综合征翻修手术辅助手段的效果,2012至2020年共治疗59条神经,其中32条使用PECM包裹。调整基线特征后,包裹组McGowan评分较单纯翻修组改善0.43分(95%CI 0.01-0.86,p=0.049),无植入物相关并发症,包裹组84.4%患者最终随访获优或良。
要点
- PECM包裹组McGowan评分较单纯翻修组改善0.43分(95%CI 0.01-0.86,p=0.049)。
- 包裹组84.4%患者最终随访获优或良,无植入物相关并发症。
- PECM可能通过减少粘连和促进生理滑动改善临床症状。
核心结论
- 使用PECM似乎可改善临床症状,可能通过减少粘连和促进生理滑动实现。
研究设计与样本
- 回顾性队列研究,纳入2012至2020年诊断为神经病理性疼痛并接受翻修手术的患者,分为A组(仅翻修手术)和B组(翻修手术联合PECM神经包裹)。
- 共治疗59条神经,其中32条使用辅助PECM包裹。
- 采用McGowan分级在基线和术后六个月评估疾病严重程度,使用线性回归模型评估尺神经包裹对六个月临床结局的影响。
主要发现
- 基线时两组疾病严重程度相似。
- 调整基线特征差异后,B组McGowan评分较A组改善0.43分(95%CI 0.01-0.86,p=0.049)。
- 无植入物相关并发症。
- B组最终随访时84.4%患者获优或良结局。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The wrapping technique aims to protect the nerve when the nerve bed is compromised or more commonly to prevent the recurrence of scar tethering following neurolysis. A wrap provides a physical barrier to scar and helps restore the paraneurial gliding layer. This study aimed to evaluate the results of the AxoGuard® nerve protector, a porcine-derived submucosal extracellular matrix (PECM), used as an adjunct in persistent or recurrent cubital tunnel syndrome (CuTS). This retrospective cohort study evaluated patients diagnosed, between 2012 and 2020, with neuropathic pain who underwent revision surgery. Patients were categorised into Group A (revision surgery only) and Group B (revision surgery and adjunctive PECM nerve wrapping). Disease severity was scored at the baseline and six months post-operatively using the McGowan classification. A linear regression model was used to assess the effect of wrapping the ulnar nerve on the clinical outcome at six months. Fifty-nine nerves were treated; among them, adjunctive PECM wrapping was used in 32 nerves. Disease severity at baseline was similar between the groups. After adjusting for differences in baseline characteristics, participants in Group B improved with a significant difference of 0.43 McGowan points over Group A (95% CI (0.01-0.86), p = 0.049). There were no implant-related complications. Group B improved with excellent or good outcomes in 84.4% patients at the final follow-up. Persistent or recurrent CuTS were associated with neuropathic pain and significant nerve scar tether. The use of PECM appears to lead to improved clinical symptoms, possibly by reducing adhesions and encouraging physiological glide. LEVEL OF EVIDENCE: Level III evidence.
引用
- Burahee AS, Duraku LS, Bosman R, et al. Porcine submucosal extracellular matrix wrapping of the ulnar nerve in revision cubital tunnel surgery. J Plast Reconstr Aesthet Surg. 2024. PMID: 39270614. doi:10.1016/j.bjps.2024.08.072
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。