点阵二氧化碳激光治疗烧伤瘢痕:接受与未接受激光治疗患者报告结局的比较
本研究基于单中心烧伤模型系统国家数据库,比较接受门诊点阵二氧化碳激光治疗的烧伤幸存者与匹配的未接受激光治疗者的患者报告结局。共纳入287名成人烧伤幸存者(激光组65例,对照组222例),在12个月和24个月随访时,激光治疗与所考察的各项患者报告结局均无关联。作者认为需进一步研究开发对激光治疗临床变化更敏感的患者报告结局测量工具。
要点
- 激光组与对照组在烧伤面积、保险类型、吸入性损伤和呼吸机需求方面存在显著差异。
- 在12个月和24个月随访时,激光治疗与生活满意度、心理和躯体健康评分及疼痛强度均无关联。
- 作者认为需进一步研究开发对激光治疗临床变化更敏感的患者报告结局测量工具。
核心结论
- 激光治疗在12个月和24个月随访时与所考察的患者报告结局均无关联。
- 作者认为需进一步研究开发对激光治疗临床变化更敏感的患者报告结局测量工具。
研究设计与样本
- 研究纳入单中心烧伤模型系统国家数据库中的参与者,将接受门诊激光治疗烧伤瘢痕者与匹配的未接受激光治疗的烧伤幸存者进行比较。
- 研究人群包括287名成人烧伤幸存者,其中激光组65例,对照组222例。
- 采用回归分析检验激光治疗与各结局在12个月和24个月时的关联。
主要发现
- 两组间显著差异包括:烧伤面积(激光组14.9,标准差13.5;对照组8.9,标准差11.1;P < .001)。
- 两组间保险类型差异显著(P = .036)。
- 两组间吸入性损伤比例差异显著(激光组17.2% vs 对照组2.7%;P < .001)。
- 两组间呼吸机需求比例差异显著(激光组27.7% vs 对照组13.5%;P = .013)。
- 激光治疗在12个月和24个月随访时与生活满意度量表、退伍军人兰德调查心理和躯体成分摘要及PROMIS疼痛强度量表均无关联。
局限性
- 作者指出需进一步研究开发对激光治疗临床变化更敏感的患者报告结局测量工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Burn reconstruction outcomes are an area of growing investigation. Although there is evidence of measured physical improvements in scar characteristics after laser treatment, there is little information on patient-reported outcomes. The purpose of this study is to compare patient-reported outcomes between burn survivors with and without laser treatment. The study included participants in the Burn Model System National Database at a single center; participants that received outpatient laser treatment for burn scars were compared to a matched group of burn survivors that did not receive laser. The following outcomes were examined: Satisfaction With Life Scale, Mental and Physical Component Summary of the Veterans Rand Survey, and the Patient-Reported Outcomes Measurement Information System (PROMIS) Pain Intensity Scale. Regression analyses examined the associations between laser treatment and each outcome at 12 and 24 months. The study population included 287 adult burn survivors (65 laser group and 222 control group). The significant differences found between the 2 groups included: burn size (laser: 14.9, 13.5 SD, control: 8.9, 11.1 SD; P < .001), insurance type (P = .036), inhalation injury (laser: 17.2%, control: 2.7%; P < .001), and ventilator requirement (laser: 27.7%, control: 13.5%; P = .013). Laser treatment was not associated with any of the outcomes at both follow-up time points. Further research is needed to develop patient-reported outcome measures that are more sensitive to the clinical changes experienced by burn survivors receiving laser treatment.
引用
- Abouzeid C, Friedstat J, Goldstein R, et al. Fractional CO2 Laser for Burn Scars: A Comparison of Patient-Reported Outcomes Between Those With and Without Laser Treatment. J Burn Care Res. 2024. PMID: 38943510. doi:10.1093/jbcr/irae129
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。