人工智能评估真实结局:72例连续筋膜下隆乳提升术联合平滑圆形假体与P4HB支架的支持分析

Artificial Intelligence, Genuine Outcome: Analysis of 72 Consecutive Cases of Subfascial Augmentation Mastopexy With Smooth Round Implants Supported by P4HB Scaffold.
PubMed 文献 · Aesthet Surg J · 2024-01-01

研究纳入72例(初次46例、二次26例)接受筋膜下平滑圆形假体联合P4HB支架隆乳提升术的患者,用三维人工智能软件测量下极拉伸。随访平均24.8个月,1年和3年下极弓伸长分别为8.04%和9.44%,未报告复发下垂、假体移位或包膜挛缩。假体大小与下极拉伸显著相关(P<.05),>400 cc时P=.0011。

要点

  • 随访平均24.8个月,未报告复发下垂、假体移位或包膜挛缩。
  • 下极弓伸长1年8.04%、3年9.44%,与既往报道相比更优。
  • 假体大小与下极拉伸显著相关(P<.05),>400 cc时P=.0011。

核心结论

  • 这是已发表的最大系列,报告GalaFLEX用于隆乳提升术的长期结果(长达45个月),提示其在筋膜下平面联合平滑假体隆乳时对下极稳定性具有支持作用。

研究设计与样本

  • 研究纳入2020年3月至2023年12月由G.B.手术的151例患者中72例随访至少12个月者,其中初次隆乳提升术46例、二次26例,均使用筋膜下圆形平滑假体与P4HB支架支持。
  • 所有测量采用三维人工智能软件,并分析下垂复发及所有并发症。

主要发现

  • 随访平均24.8个月,未报告复发下垂、下极下沉、假体移位或包膜挛缩。
  • 下极弓伸长在1年和3年分别为8.04%和9.44%,与既往报道相比更优。
  • 假体大小与下极拉伸呈统计学显著相关(P<.05),>400 cc时P=.0011,初次病例P=.1376。
  • 第一年观察到容量自上极向下极渐进性再分布,此后基本稳定。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Ptosis recurrence often leads to unsatisfactory results after mastopexy, even more so when additional stress is provided by implants on compromised native tissue. The poly-4-hydroxybutyrate(P4HB) scaffold (GalaFLEX) with its favorable safety profile and proven long-term mechanical strength represents a preferred option for soft tissue support. OBJECTIVES: The primary endpoint was assessment of lower pole stretch from the early postoperative period up to 3 years. METHODS: Out of 151 patients who underwent surgery by G.B. from March 2020 to December 2023, a total of 72 with a 12-month-mininum follow-up who had primary (46) or secondary (26) augmentation mastopexy with subfascial round smooth implants and P4HB scaffold support were included in the study. Three-dimensional artificial intelligence software was utilized for all measurements. Further analysis included evaluation of ptosis recurrence and all complications. RESULTS: No recurrent ptosis, bottoming out, implant displacement, or capsular contracture was reported during follow-up (mean, 24.8 months). The lower pole arch's elongation was 8.04% and 9.44% at 1 and 3 years respectively, comparing favorably with previous reports. Statistically significant correlation (P < .05) between implant size and lower pole stretch was noted, this being greater for larger implants (> 400 cc; P = .0011) and primary cases (P = .1376). Progressive volume redistribution from upper to lower pole was observed in the first year, with substantial stability thereafter. CONCLUSIONS: This is the largest published series reporting long-term results (up to 45 months) in mastopexy augmentation with GalaFLEX, suggesting its supportive role in lower pole stability even in the setting of concurrent breast augmentation with smooth implants in a subfascial plane.