单中心回顾性病例系列纳入10例双侧DIEP皮瓣乳房再造后行机器人修复腹直肌分离和/或腹部膨隆及疝的患者,采用腹直肌后鞘折叠与大网孔补片加强,无中转开放、30天内无并发症,作者认为该技术有效、并发症率低,应考虑优先于开放修复。
要点
- 10例DIEP皮瓣再造后腹直肌分离(≤5 cm)、腹部膨隆和/或疝患者行机器人腹直肌后鞘折叠加补片加强修复。
- 无患者中转开放手术,30天内无并发症发生。
- 作者认为该技术有效、并发症率低,应考虑优先于开放修复。
核心结论
- 对于DIEP皮瓣乳房再造后出现供区并发症的患者,机器人微创修复腹直肌分离和/或腹部膨隆伴疝可联合补片加强完成,该技术有效、并发症率低,作者认为应考虑优先于开放修复。
研究设计与样本
- 单中心回顾性病例系列,纳入10例接受双侧DIEP皮瓣乳房再造并后续行机器人修复腹直肌分离和/或腹部膨隆及疝的患者,回顾术前人口学资料与术后临床结局。
主要发现
- 平均年龄49岁(范围41-63),平均BMI 31 kg/m2(范围26-44)。
- 每侧皮瓣平均获取穿支数2.5(范围1-4)。
- 平均腹直肌分离3.95 cm(范围2-5),平均疝大小5.8 cm2(范围1-15)。
- 8例住院1晚,2例机器人修复当天回家;无中转开放,30天内无并发症。
关键数值与推荐
- 腹直肌分离达5 cm、腹部膨隆及任何合并的腹壁/脐疝均以机器人腹直肌后鞘折叠联合大网孔补片加强修复。
临床怎么用
- 作者认为,对DIEP皮瓣乳房再造后出现供区并发症者,机器人微创修复腹直肌分离和/或腹部膨隆伴疝联合补片加强有效、并发症率低,应考虑优先于开放修复。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The deep inferior epigastric artery perforator (DIEP) flap is the gold standard in autologous breast reconstruction. Despite advances in perforator dissection, abdominal morbidity still occurs. Traditional rectus diastasis (RD), abdominal bulge, and hernia repair with open techniques are associated with higher complication rates and recurrence. OBJECTIVES: We present a novel case series of robotic repair of symptomatic RD and/or abdominal bulge with concurrent hernia following DIEP flap surgery. METHODS: A single-center, retrospective review was conducted of 10 patients who underwent bilateral DIEP flap breast reconstruction and subsequent robotic repair of RD and/or abdominal bulge and hernia. Preoperative demographics and postoperative clinical outcomes were reviewed. RD up to 5 cm, abdominal bulge, and any concurrent ventral/umbilical hernias were repaired robotically with retrorectus plication and macroporous mesh reinforcement. RESULTS: The average age and BMI were 49 years (range 41-63) and 31 kg/m2 (range 26-44), respectively. The average number of perforators harvested per flap was 2.5 (range 1-4). Average RD and hernia size were 3.95 cm (range 2-5) and 5.8 cm2 (1-15), respectively. Eight patients stayed 1 night in the hospital, and 2 went home the same day as the robotic repair. No patients were converted to open technique and none experienced complications within 30 days. CONCLUSIONS: For patients who experience donor site morbidity following DIEP flap breast reconstruction, minimally invasive robotic repair of RD and/or abdominal bulge with hernia can be performed with mesh reinforcement. This technique is effective, with low complication rates, and should be considered over open repair.
引用
- Herold K, Stoddard T, Rodriguez-Unda N, et al. Robotic Repair: An Alternative Technique for Rectus Diastasis and Abdominal Bulge Following DIEP Flap Breast Reconstruction. Aesthet Surg J. 2024. PMID: 38500393. doi:10.1093/asj/sjae059
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。