文献速递显微修复重建创面修复

「解剖外血管蒂改道」:在不利临床情况下获取显微外科重建新受区血管的替代技术

"Extra-anatomical Pedicle Rerouting" An alternative technique to obtain new recipient vessels for microsurgical reconstruction in unfavorable clinical situations.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2024-02-02

本文报告15例位于躯干或上下肢、病因多样(肿瘤切除、创伤、既往手术)的缺损患者,在本机构接受解剖外血管蒂改道(EPR)游离皮瓣重建。共转移15块皮瓣(6块股前外侧皮瓣、6块背阔肌/胸背动脉穿支皮瓣、3块腹壁下深动脉穿支皮瓣),平均改道血管长度6.53 cm,平均手术时间420分钟,无重大并发症,3例出现轻微伤口裂开并保守处理。作者认为EPR技术在身体不同区域作为获取健康受区血管的替代方案可靠且可重复。

要点

  • 15例躯干或上下肢缺损患者采用EPR技术行游离皮瓣重建,共转移15块皮瓣。
  • 平均改道血管长度6.53 cm,平均手术时间420分钟,无重大并发症。
  • 3例出现轻微伤口裂开并保守处理。

核心结论

  • 作者认为EPR技术在身体不同区域作为获取健康受区血管的替代方案可靠且可重复。

研究设计与样本

  • 本机构15例缺损患者接受EPR游离皮瓣重建的病例系列,记录手术数据、术后经过和并发症,并记录临床和照片随访。

主要发现

  • 共转移15块皮瓣(6块股前外侧皮瓣、6块背阔肌/胸背动脉穿支皮瓣、3块腹壁下深动脉穿支皮瓣),用于肿瘤(11例)和创伤后(4例)缺损。
  • 改道的血管包括胸肩峰、旋肱后、胸背、腹壁下深、旋股外侧、胫前和腓肠内侧血管蒂。
  • 平均改道血管长度6.53 cm,平均手术时间420分钟。
  • 无重大并发症;3例出现轻微伤口裂开并保守处理。

临床怎么用

  • 作者认为EPR技术可在解剖和手术不利的临床情况下作为获取健康受区血管的替代方案。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Lack of adequate recipient vessels in certain anatomically unfavorable locations or in complex clinical situations is still a limitation to successful microsurgical transfer. To address such complex cases, advanced microsurgical techniques should be applied. In this paper, the authors describe their experience with the Extra-anatomical Pedicle Rerouting (EPR) technique, an alternative approach that was used in selected cases throughout the body to obtain healthy recipient vessels for microsurgical reconstruction in unfavorable clinical situations where suitable recipient vessels were difficult to find. PATIENTS AND METHODS: Fifteen patients with defects of variable etiology (oncological resection, trauma, previous surgeries) located in the trunk or upper and lower extremities received EPR free flap reconstruction at our Institution. Operative data, postoperative course, and complications were recorded. Clinical and photographic follow-ups were also documented. RESULTS: A total of 15 flaps (6 antero-lateral thigh (ALT), 6 latissimus dorsi/thoracodorsal artery perforator flap (LD/TDAP), 3 deep inferior epigastric artery perforator flap (DIEP)) were transferred adopting the EPR technique for oncological (11) and post-traumatic (4) defects. According to the different clinical scenarios, the rerouted vessels were the thoraco-acromial, posterior circumflex humeral, thoracodorsal, deep inferior epigastric, lateral circumflex femoral, anterior tibial, and medial sural pedicles. Mean length of the rerouted vascular conduits was 6.53 cm. Mean operative time was 420 minutes. No major complications were registered. Minor wound dehiscence was observed and managed conservatively in 3 patients. CONCLUSIONS: The EPR technique proved to be useful in a reliable and reproducible manner in different regions of the body as an alternative solution to obtain healthy recipient vessels in anatomically and surgically unfavorable clinical situations.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。