烧伤中心安装智能监测技术及附加措施对医务人员手卫生依从性的影响:一项准实验纵向试验
该准实验纵向试验在烧伤中心开展11个月,评估智能监测技术安装(IMTI)及附加措施对医务人员手卫生依从性的影响。41名医务人员完成15202次手卫生事件,共观察20095次手卫生机会。第二阶段IMTI定义的手卫生执行率71.2%和第三阶段80.5%均高于直接观察获得的58.5%,第三阶段所有医务人员手卫生依从性持续升高。
要点
- IMTI定义的手卫生执行率在第二阶段为71.2%、第三阶段为80.5%,均高于直接观察的58.5%。
- 第二阶段护士、物理治疗/麻醉技师和保洁人员手卫生依从性显著增加,医生增加不显著。
- 第三阶段IMTI联合附加措施后,所有医务人员手卫生依从性呈持续升高趋势。
核心结论
- IMTI显著提高了手卫生执行率;IMTI与附加措施联合作为WHO推荐的多模式策略组成部分,似乎影响医务人员手卫生依从性升高趋势的可持续性。
研究设计与样本
- 准实验纵向试验,为期十一个月,分三阶段:第一阶段用直接观察评估基础手卫生依从性,第二阶段评估IMTI记录的系统定义手卫生执行率,第三阶段确定IMTI及附加措施的效果。
- 41名医务人员完成15202次手卫生事件,共观察20095次手卫生机会;安装前阶段455次机会,安装后总期间19640次机会。
主要发现
- IMTI定义的手卫生执行率在第二阶段为71.2%、第三阶段为80.5%,均普遍高于直接观察获得的手卫生依从性58.5%。
- 第二阶段护士、物理治疗/麻醉技师和保洁人员手卫生依从性显著增加,医生增加不显著。
- 第三阶段IMTI联合附加措施后,所有医务人员手卫生依从性呈持续升高。
关键数值与推荐
- 手卫生依从性依据世界卫生组织(WHO)定义的「手卫生5时刻」概念评估。
- IMTI定义的手卫生执行率第二阶段71.2%、第三阶段80.5%,直接观察手卫生依从性58.5%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The increasing development of intelligent technologies for hand hygiene (HH) compliance audit has the potential to create an alternative to direct observation (DO), which is still considered the gold standard but has disadvantages such as lack of standardized monitoring practices, Hawthorne effect, insufficient sample size, and time/resource consumption. We aimed to share our preliminary results on the impacts of intelligent monitoring technology installation (IMTI) and additional modalities on healthcare workers' (HCWs') HH compliance in a Burn Center, according to the "5 Moments of HH" concept defined by the World Health Organization (WHO). METHODS: A quasi-experimental longitudinal trial was conducted over eleven months.The first phase of the three-stage study evaluated basic HH compliances obtained by DO. The system-defined HH performances, which IMTI recorded, were assessed in the second phase. Finally, the effect of IMTI and additional modalities was determined in the third stage. RESULTS: 15202 HH events were performed by 41 HCWs, and a total of 20095 HH opportunities were observed. Four hundred fifty-five opportunities were in the preinstallation phase, and 19640 were during the total post-installation period. IMTIdefined performance rates in both Phase 2 (71.2%) and Phase 3 (80.5%) were generally considerably higher than HH compliances obtained from DO (58.5%). Nurses, physical therapy /anesthesia technicians, and housekeeping personnel showed significant increases, which was insignificant in physicians in phase 2. Meanwhile, a sustained increase was observed regarding IMTI and additional modalities of HH compliance of all HCWs in Phase 3. CONCLUSION: IMTI has significantly increased HH performance rates. Furthermore, combining the IMTI with additional modalities as components of a multimodal strategy recommended by WHO appears to affect the sustainability of the increasing trend of HCWs' HH compliance.
引用
- Gurbuz K, Das K, Demir M, et al. Impacts of intelligent monitoring technology installation and additional modalities on hand hygiene compliance in a burn center: A quasi-experimental longitudinal trial. Burns. 2024. PMID: 38458960. doi:10.1016/j.burns.2024.02.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。