FALD-V:FALD皮瓣脂肪移植术前体积评估的预测公式
本研究为2020年9月至2023年4月的前瞻性临床研究,纳入66个FALD皮瓣,术前超声测量背部皮下皮岛厚度(SPT),均值11.95 mm(SD 4.56)。SPT与体重指数(BMI)显著相关(r=0.640,p<0.0001)。利用脂肪容量比113%建立预测公式FALD-V:[-509+12.32×BMI+11.71×皮岛宽度+17.43×皮岛高度]×1.13,交叉验证确认公式准确性(r=0.810)。
要点
- FALD-V公式基于BMI、皮岛宽度和皮岛高度预测FALD皮瓣所需脂肪移植量。
- SPT与BMI显著相关(r=0.640,p<0.0001),脂肪容量比为113%。
- 交叉验证显示公式准确性良好(r=0.810),可作为FALD皮瓣一期全自体乳房再造规划的辅助工具。
核心结论
- FALD-V可作为FALD皮瓣一期全自体乳房再造规划中的创新辅助工具,并提供了免费WebApp(www.braflap.com及www.breast-v.com)供iOS和Android设备使用。
研究设计与样本
- 前瞻性临床研究,2020年9月至2023年4月,共收集66个FALD皮瓣的数据,所有患者术前接受背部超声扫描评估皮下皮岛厚度(SPT),并进行回归分析。
主要发现
- SPT均值为11.95 mm(SD 4.56),SPT与BMI显著相关(r=0.640,p<0.0001)。
- 预测公式中BMI、皮岛宽度和皮岛高度的统计显著性分别为p<0.001、p=0.0483、p=0.0154。
- 交叉验证确认公式准确性(r=0.810)。
关键数值与推荐
- FALD-V预测公式:[-509+12.32×BMI+11.71×皮岛宽度+17.43×皮岛高度]×1.13,其中脂肪容量比为113%。
临床怎么用
- 作者认为FALD-V可作为FALD皮瓣一期全自体乳房再造规划中的创新辅助工具,并提供了免费WebApp供iOS和Android设备使用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The fat-augmented latissimus dorsi (FALD) flap is an evolution of the traditional latissimus dorsi (LD) flap, which allows to obtain a total autologous breast reconstruction (BR) avoiding the use of breast implants. The aim of this study was to develop a predictive preoperative formula in order to estimate and optimize the amount of fat to be transferred during FALD flap BR, using only anthropometric measurements. METHODS: We conducted a prospective clinical study between September 2020 and April 2023. All patients underwent back pre-operative ultrasound scan to assess the subcutaneous skin paddle thickness (SPT) and a regression analysis was performed to evaluate which anthropometric variable had a better correlation with this thickness. RESULTS: Data from 66 FALD flaps were collected. The mean SPT was 11.95 mm (SD 4.56). A significant correlation between SPT and body mass index (BMI) was found (r = 0.640, p < 0.0001). Using the fat-to-capacity ratio (113%), the following formula (the FALD-V) was developed to predict the needed fat transfer into FALD flap: [-509 + 12.32 × BMI + 11.71 × skin paddle width + 17.43 × skin paddle height] × 1.13. The considered variables (BMI, skin paddle width and skin paddle height) were statistically significant (p < 0.001, p = 0.0483, p = 0.0154, respectively). The cross-validation confirmed the accuracy of the formula (r = 0.810). CONCLUSION: The FALD-V can be used as an innovative complimentary device in the planning of FALD flap one-stage total autologous BR. To enhance its application, a 3.0 WebApp at www.braflap.com (and www.breast-v.com) is available free of charge for both iOS and Android devices. LEVEL OF EVIDENCE: II.
引用
- Longo B, D'Orsi G, Farcomeni A, et al. The FALD-V: A predictive formula for preoperative volume assessment of adipose tissue transplantation in FALD flap. J Plast Reconstr Aesthet Surg. 2024. PMID: 38340688. doi:10.1016/j.bjps.2024.01.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。