文献速递乳房整形与再造美容整形

优化乳房增大术中假体宽度选择:基于患者体表标志定位的三维乳房模拟研究

Optimizing Implant Width Selection in Breast Augmentation: Insights From On-Patient Landmark Positioning in 3-Dimensional Breast Simulation.
PubMed 文献 · Aesthet Surg J · 2024-01-01

该研究回顾性分析乳房增大术患者数据,比较临床评估(CA)与Vectra三维模拟自动(VA)及手动(VM)定位标志所测乳房宽度的变化率,并与实际植入假体宽度对比。结果显示CA变化率显著低于VA和VM(P<.05),VM显著低于VA(P<.05),各组与实际假体宽度均呈显著正相关。作者认为Vectra是有价值的辅助工具,但仅依赖自动标志定位可能不准确,临床判断在制定可靠手术计划上优于模拟程序。

要点

  • 临床评估的乳房宽度变化率显著低于Vectra自动和手动定位(P<.05)。
  • 手动定位变化率显著低于自动定位(P<.05),各组均与实际假体宽度正相关。
  • 作者认为临床判断在制定可靠手术计划上优于模拟程序。

核心结论

  • Vectra XT三维模拟程序是乳房增大术的有价值辅助工具,但仅依赖自动标志定位可能导致乳房尺寸评估不准确。
  • 作者认为在制定可靠手术计划时,临床判断优于模拟程序。

研究设计与样本

  • 作者对乳房增大术患者数据进行了回顾性分析,通过临床评估(CA)以及Vectra程序自动(VA)和手动(VM)定位标志获取乳房宽度测量值。
  • 研究还考虑内外侧乳房组织厚度,并将各组建议的假体基底宽度与手术实际植入假体宽度进行比较。

主要发现

  • 与CA测量相比,VA和VM的变化率均显著更高(P<.05)。
  • VM的变化率显著低于VA(P<.05)。
  • 各组建议假体宽度与实际植入假体宽度均呈显著正相关。

临床怎么用

  • 作者提出可在创建Vectra图像前在患者体表标记标志点,以实现标准化测量。
  • 作者认为临床判断在制定可靠手术计划上优于模拟程序。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Vectra XT 3D simulation program is a valuable tool for implant selection during the decision-making process regarding breast augmentation. The software allows for the assignment of automatically or manually positioned anatomical landmarks and provides accompanying measurements. OBJECTIVES: This study aimed to present a strategy for standardizing landmark placement on Vectra images during primary breast augmentations, optimizing implant selection and ensuring consistency in breast width data collection. METHODS: The author performed a retrospective analysis of patient data in which breast width measurements were obtained through clinical assessment (CA) and the Vectra program with both automatically (VA) and manually (VM) placed landmarks. Consideration was also given to the thickness of medial and lateral breast tissues. The suggested implant base width from all groups was then compared to the actual implant placed during the surgical procedure. RESULTS: Comparing the change rates with the actual implant width revealed that rates in CA measurements were significantly lower than those in VA (P < .05), and similarly lower than those in VM (P < .05). Furthermore, change rates in VM were significantly lower than in VA (P < .05). Each group showed a significant positive correlation with the actual implant width. CONCLUSIONS: The Vectra XT 3D simulation program is a valuable adjunct in breast augmentation. However, relying on it solely may lead to inaccuracies in the assessment of breast dimensions due to automatic landmarking. To achieve standardized measurements, landmarks can be marked on the patient before creating the Vectra image. Our results underline the superiority of clinical judgment to simulation programs when establishing a reliable surgical plan.

来源:Aesthet Surg J,查看原文。版权归原作者所有。

引用

  1. Akgun Demir I. Optimizing Implant Width Selection in Breast Augmentation: Insights From On-Patient Landmark Positioning in 3-Dimensional Breast Simulation. Aesthet Surg J. 2024. PMID: 38377409. doi:10.1093/asj/sjae040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。