即刻DIEP皮瓣乳房再造中采用管状皮瓣分期即刻乳头再造
研究纳入2019年1月至2020年12月60例接受乳房切除(含乳头乳晕复合体)及即刻DIEP皮瓣乳房再造的女性患者,利用DIEP皮瓣上梯状蒂皮瓣卷成管状,1周后游离端嵌入再造乳房 mound 未来乳头位置,1个月血运重建后断蒂行乳头再造;所有再造乳房和乳头术后存活良好,乳头凸度术后即刻平均12.5±2.0 mm,1年随访降至9.4±1.5 mm,凸度损失24.9%±1.8%,51例患者对乳房和乳头再造总体印象为很好或好。
要点
- 所有再造乳房和乳头术后存活良好。
- 乳头凸度术后即刻平均12.5±2.0 mm,1年随访降至9.4±1.5 mm,凸度损失24.9%±1.8%。
- 51例患者对乳房和乳头再造总体印象为很好或好。
核心结论
- 作者认为该技术可改善再造乳头凸度的维持并获得美学可接受的结果,且不造成DIEP皮瓣组织损失、乳房mound变形或额外瘢痕。
研究设计与样本
- 研究纳入2019年1月至2020年12月共60例女性患者,均接受乳房切除(含乳头乳晕复合体)及即刻DIEP皮瓣乳房再造。
- 从DIEP皮瓣上掀起梯状蒂皮瓣卷成管状,1周后将管状皮瓣游离端嵌入再造乳房mound未来乳头位置,血运重建1个月后断蒂,将管状皮瓣用于乳房mound顶部再造新乳头。
主要发现
- 所有再造乳房和乳头术后存活良好。
- 乳头凸度术后即刻平均12.5±2.0 mm,1年随访降至9.4±1.5 mm,凸度损失为初始测量的24.9%±1.8%。
- 51例患者认为乳房和乳头再造的总体印象为很好或好。
临床怎么用
- 作者认为该技术可改善再造乳头凸度的维持并获得美学可接受的结果,且不造成DIEP皮瓣组织损失、乳房mound变形或额外瘢痕。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In the setting of immediate breast reconstruction by deep inferior epigastric artery perforator (DIEP) flap, the excessive DIEP flap skin is de-epithelialized and then buried under the mastectomy skin. In this study, by virtue of tube flap technique, we hypothesize that the skin supposed to be abandoned could be transferred to the apex of reconstructed breast mound for nipple reconstruction. METHODS: A total of 60 female patients were recruited between January 2019 and December 2020. All these patients underwent mastectomy including nipple-areola complex and immediate DIEP flap breast reconstruction. A ladder-shaped pedicled flap was raised from the DIEP flap and rolled into a tube. The free end of tube flap was inset into the future nipple position of the reconstructed breast mound 1 week later. After revascularization for 1 month, we divided the previous pedicle and used the tube on the apex of the breast mound to recreate a new nipple. RESULTS: All reconstructed breasts and nipples survived well postoperatively. The average nipple projection was 12.5 ± 2.0 mm immediately after the surgery, which gradually decreased to 9.4 ± 1.5 mm at 1-year follow-up, with the projection loss from the initial measurement as 24.9% ± 1.8%. In total, 51 patients considered the overall impression of breast and nipple reconstruction to be very good or good. CONCLUSIONS: We provided an ideal technique that could improve the maintenance of reconstructed nipple projection and have aesthetically acceptable outcomes, without DIEP flap tissue loss, breast mound distortion, or additional scars.
引用
- Chu C, Zhang W, Zhang Y, et al. Staged Immediate Nipple Reconstruction With Tube Flap in Immediate Deep Inferior Epigastric Artery Perforator Flap Breast Reconstruction. Ann Plast Surg. 2024. PMID: 38394267. doi:10.1097/SAP.0000000000003768
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。