本研究检索Westlaw与LexisNexis数据库中整形手术期间烧伤和火灾相关医疗过失诉讼的陪审团裁决与和解案例,共纳入46例。手术器械过热和电灼设备是最常见诉讼机制,整形外科医生为被告40例(87%)。作者认为此类绝不事件由人为错误或疏忽所致,应关注器械误用并考虑强制功能与额外保障措施。

要点

  • 手术器械过热和电灼设备是整形手术烧伤诉讼最常见机制。
  • 46例中整形外科医生为被告40例(87%)。
  • 作者认为绝不事件由人为错误或疏忽导致,建议考虑强制功能与额外保障措施。

核心结论

  • 整形与重建外科中导致烧伤的绝不事件最终由人为错误或疏忽造成。
  • 应重点关注过热手术器械和电灼设备的误用,以改善患者安全并降低医疗过失风险。
  • 作者认为可考虑采用强制功能和额外保障措施,以尽量减少代价高昂的诉讼和对患者不必要的严重伤害。

研究设计与样本

  • 研究检索Westlaw和LexisNexis数据库中整形手术期间发生烧伤和火灾相关医疗过失诉讼的陪审团裁决与和解案例。
  • Westlaw检索词包括「burn & injury & plastic」和「fire & injury & "plastic surg!"」,LexisNexis检索词包括「burn & injury & "plastic surg!"」和「fire & injury & "plastic surg!"」。
  • 共46例符合纳入标准。

主要发现

  • 手术器械过热和电灼设备是最常见的诉讼机制。
  • 整形外科医生为被告40例(87%)。
  • 43%的病例裁决支持被告,33%的病例裁决支持原告。
  • 最常见的错误类型为电灼设备操作不当6例(13%)、加热手术器械6例(13%)和局部酸剂2例(4%)。

临床怎么用

  • 作者认为应重点关注过热手术器械和电灼设备的误用,以改善患者安全并降低医疗过失风险。
  • 作者认为可考虑采用强制功能和额外保障措施,以尽量减少代价高昂的诉讼和对患者不必要的严重伤害。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Burns and fires in the operating room are a known risk and their prevention has contributed to many additional safety measures. Despite these safeguards, burn injuries contribute significantly to the medical malpractice landscape. The aim of the present study is to analyze malpractice litigation related to burn and fire injuries in plastic and reconstructive surgery, identify mechanisms of injury, and develop strategies for prevention. METHODS: The Westlaw and LexisNexis databases were queried for jury verdicts and settlements in malpractice lawsuits related to burn and fire injuries that occurred during plastic surgery procedures. The Boolean terms included "burn & injury & plastic", "fire & injury & "plastic surg!"" in Westlaw, and "burn & injury & "plastic surg!"", "fire & injury & "plastic surg!"" in LexisNexis. RESULTS: A total of 46 cases met the inclusion criteria for this study. Overheated surgical instruments and cautery devices were the most common mechanisms for litigation. Plastic surgeons were defendants in 40 (87%) cases. Of the included cases, 43% were ruled in favor of the defendant, while 33% were ruled in favor of the plaintiff. Mishandling of cautery devices 6 (13%), heated surgical instruments 6 (13%), and topical acids 2 (4%) were the most common types of errors encountered. CONCLUSION: Never events causing burn injury in plastic and reconstructive surgery are ultimately caused by human error or neglect. The misuse of overheated surgical instruments and cauterizing devices should be the focus for improving patient safety and reducing the risk of medical malpractice. Forcing functions and additional safeguards should be considered to minimize the risk of costly litigation and unnecessary severe harm to patients.