该回顾性研究纳入35例接受单侧PAP皮瓣乳房再造的患者,分析术前CTA影像以评估大腿后侧穿支的影像学架构,并用笛卡尔坐标系映射穿支。66侧大腿平均穿支数为3.2,所选穿支在起点、收肌间隙中点、深筋膜处平均直径分别为2.7 mm、2.2 mm、1.7 mm。作者认为采用容积渲染技术的CTA是研究大腿后侧穿支活体影像解剖的有价值方法。

要点

  • 66侧大腿平均穿支数为3.2,所选穿支起点平均直径2.7 mm(标准差±0.6 mm)。
  • 术中穿支距股薄肌后缘3.22 cm(标准差±0.87),距臀沟8.98 cm(标准差±1.44)。
  • 作者认为容积渲染CTA是研究大腿后侧穿支活体影像解剖的有价值方法。

核心结论

  • 作者认为采用容积渲染技术的CTA是研究大腿后侧穿支活体放射解剖的有价值方法。

研究设计与样本

  • 回顾性研究,纳入35例接受单侧PAP皮瓣乳房再造的患者,分析术前CTA扫描并评估穿支特征。
  • 穿支采用笛卡尔坐标系映射,数据经解剖标志归一化后重叠,并分析围手术期与术后结果,比较影像学与术中结果。

主要发现

  • 排除2份CTA扫描后,共检查66侧大腿,平均穿支数为3.2。
  • 所选穿支平均直径在起点为2.7 mm(标准差±0.6 mm),在收肌间隙中点为2.2 mm(标准差±0.4 mm),在深筋膜为1.7 mm(标准差±0.3 mm)。
  • 平均脂肪组织厚度在深筋膜为3.35 cm(标准差±0.94),在收肌间隙中点为3.59 cm(标准差±1.19)。
  • 术中穿支距股薄肌后缘3.22 cm(标准差±0.87),距臀沟8.98 cm(标准差±1.44)。
  • 识别出距y轴9.33 cm(标准差±4.81)、距x轴7.48 cm(标准差±1.88)的影像学区域。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The popularity of the profunda femoris artery perforator (PAP) flap is increasing; however, knowledge concerning the standardization of radiological findings and their clinical implications is limited. We evaluated the radiological architecture of posterior thigh perforators using Computed Tomography Angiography (CTA) to identify landmarks to facilitate flap dissection. METHODS: A retrospective study was conducted on 35 patients who underwent unilateral breast reconstruction with a PAP flap. The preoperative CTA scans were analyzed, and the perforator characteristics were evaluated. The perforators were mapped using a Cartesian coordinate system. Data were normalized by anatomical landmarks and overlapped. Perioperative and postoperative results were analyzed. Radiological and intraoperative were compared. RESULTS: Two CTA scans were excluded; 66 thighs were examined. The mean perforator number was 3.2. The mean diameter of chosen perforators was 2.7 mm (DS ± 0.6 mm) at the origin, 2.2 mm (DS ± 0.4 mm) at the adductor space midpoint, and 1.7 mm (DS ± 0.3 mm) at the deep fascia. The mean adipose tissue thickness was 3.35 cm (DS ± 0.94) at the deep fascia and 3.59 cm (DS ± 1.19) at the adductor space midpoint. Intraoperatively, the perforator was located 3.22 cm (DS ± 0.87) from the posterior border of the gracilis muscle and 8.98 cm (DS ± 1.44) from the inferior gluteal crease. A radiological area located 9.33 cm (DS ± 4.81) from the y-axis and 7.48 cm (DS ± 1.88) from the x-axis was identified. CONCLUSIONS: CTA using the volume-rendering technique is a valuable method to study in vivo the radiological anatomy of the posterior thigh perforators.