肩峰胸静脉增压用于乳房与胸壁重建中腹部游离皮瓣的静脉引流
回顾性分析2009至2022年间523例保留肌肉的腹直肌游离皮瓣乳房与胸壁重建,其中46例需静脉增压,24例采用肩峰胸静脉/胸肩峰静脉作为浅腹壁下静脉的受区静脉。24例女性患者随访中位26个月,1例皮瓣失败,23例完全存活,结论认为该静脉是合适的受区静脉。
要点
- 24例采用肩峰胸静脉/胸肩峰静脉增压,皮瓣平均重量740克,静脉耦合器1.5至3毫米。
- 手术时间增加10至20分钟(中位12分钟),1例皮瓣失败,23例完全存活。
- 作者结论认为肩峰胸静脉/胸肩峰静脉是乳房与胸壁缺损重建中静脉增压游离皮瓣的合适受区静脉。
核心结论
- 作者结论认为肩峰胸静脉/胸肩峰静脉是用于乳房与胸壁缺损重建的静脉增压游离皮瓣的合适受区静脉。
研究设计与样本
- 回顾性综述2009年至2022年间由资深作者完成的523例保留肌肉的腹直肌游离皮瓣乳房与胸壁重建,其中46例需要静脉增压,24例使用肩峰胸静脉/胸肩峰静脉。
主要发现
- 24例女性患者(20例乳房重建,4例胸壁重建),年龄39至72岁,随访中位26个月。
- 采用肌肉劈开与切断联合技术暴露肩峰胸静脉/胸肩峰静脉,手术时间增加10至20分钟(中位12分钟)。
- 静脉耦合器尺寸1.5至3毫米,皮瓣平均重量740克(范围460至1300克)。
- 1例皮瓣失败(以背阔肌皮瓣补救),23例皮瓣完全存活。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Supercharging the venous drainage of free abdominal flaps in breast reconstruction has been well described in the literature, with diverse options used to augment venous drainage. In this study, we present our experience in using the acromiothoracic vein (ATV)/thoracoacromial vein (TAV) as a secondary recipient vein for the superficial inferior epigastric vein (SIEV) of free, muscle-sparing transverse rectus abdominis myocutaneous flaps in breast and chest wall reconstruction. PATIENTS AND METHODS: We retrospectively reviewed 523 free, muscle-sparing transverse rectus abdominis myocutaneous flaps the senior author (H.H.K.) performed between 2009 and 2022 for breast and chest wall reconstruction; 46 cases required venous super drainage. Seventeen patients had ipsilateral SIEV anastomosed into the second internal mammary vein, 5 had ipsilateral SIEV anastomosed into flap second deep inferior epigastric vein, and 24 required the use of the (ATV)/(TAV), which will be the focus of this study. RESULTS: The study included 24 female (20 breast and 4 chest wall reconstruction) patients ranging in ages between 39 and 72 years. They had a median follow-up of 26 months. Combined muscle splitting and cutting techniques were used to expose the ATV/TAV. Increase in operative time ranged between 10 and 20 minutes (median, 12 minutes). Vein coupler sizes were 1.5 to 3 mm. The mean weight of the flap was 740 g (range, 460-1300 g). There was 1 flap failure (salvage with latissimus dorsi flap performed), whereas 23 flaps wholly survived. CONCLUSIONS: The ATV/TAV is a suitable recipient for venous supercharging free flaps used to reconstruct breast and chest wall defects.
引用
- Alsharkawy K, Youssif S, Malahias M, et al. Acromiothoracic Venous Supercharge for Abdominal-Based Free Flaps in Breast and Chest Wall Reconstruction. Ann Plast Surg. 2023. PMID: 38079318. doi:10.1097/SAP.0000000000003704
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。