文献速递瘢痕与激光创面修复

一种改良缝合技术改善高张力创面瘢痕外观的研究

A Modified Suture Technique to Improve Scar Appearance in Wounds Under High Tension.
PubMed 文献 · Ann Plast Surg · 2023-01-11

本研究在大鼠高张力创面模型中比较改良垂直褥式缝合(M-VMS)与简单间断缝合(SIS)、垂直褥式缝合(VMS)对瘢痕形成的影响。结果显示M-VMS组胶原纤维数量和密度较低,I型胶原显著降低、III型胶原显著升高,α-平滑肌肌动蛋白和TGFβ1表达较低,TGFβ2和TGFβ3三组无明显差异。作者认为M-VMS可通过减少胶原形成、肌成纤维细胞表达和TGFβ1表达减少瘢痕形成。

要点

  • M-VMS组胶原纤维数量和密度均低于SIS组和VMS组。
  • M-VMS组I型胶原显著低于其他两组,III型胶原显著高于其他两组。
  • M-VMS组α-SMA和TGFβ1表达低于其他两组,TGFβ2和TGFβ3三组无明显差异。

核心结论

  • 对于高张力创面,与SIS和VMS相比,作者提出的M-VMS技术可通过减少胶原形成、肌成纤维细胞表达和TGFβ1表达来减少瘢痕形成。

研究设计与样本

  • 研究选取健康成年雌性Sprague-Dawley大鼠三组(每组6只),麻醉后于背部切除5 cm×0.2 cm全层皮肤。
  • 创面分别采用SIS、VMS和 newly introduced modified vertical mattress suture(M-VMS,于出针点重新进针)三种方法缝合。
  • 大鼠背部安装牵引装置以形成高张力创面,每天增加牵引距离1 mm,持续20天。

主要发现

  • 愈合20天后,M-VMS组胶原纤维数量和密度均低于其他两组。
  • 免疫荧光显示M-VMS组I型胶原显著低于其他两组,而III型胶原显著高于其他两组。
  • M-VMS组α-平滑肌肌动蛋白和TGFβ1表达均低于其他两组。
  • TGFβ2和TGFβ3表达在三组间无明显差异。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The purpose of this study was to introduce a modified suture technique and to compare its effects on skin scar formation with 2 traditional suture methods: simple interrupted suture (SIS) and vertical mattress suture (VMS). Three groups of healthy adult female Sprague-Dawley rats were selected (6 replicates in each group), and the full-thickness skin of 5 cm × 0.2 cm was cut off on the back of the rats after anesthesia. The wounds were then sutured using 1 of the 3 methods for each group: SIS, VMS, and a newly introduced modified vertical mattress suture (M-VMS) technique with the needle reinsertion at the exit point. A traction device was installed on the back of the rats to achieve high tension wounds. The tensile distance was increased by 1 mm every day for 20 days. After 20 days of healing, the hematoxylin-eosin staining method was used for observation of scar morphology. The collagen production rate was measured by Masson staining, and the type I collagen and type III collagen were detected by the immunofluorescence method. Immunohistochemical staining was used to detect the expression of myofibroblast marker α-smooth muscle actin, and real-time quantitative polymerase chain reaction and Western blot techniques were used to detect the expressions of transforming growth factors TGFβ1, TGFβ2, and TGFβ3 to understand the mechanisms of scar formation. Results showed that the quantity and density of collagen fibers were both lower in the M-VMS group than in the other 2 groups. Immunofluorescence results showed that type I collagen was significantly lower, whereas type III collagen was significantly higher in the M-VMS group than in the other 2 groups. The expressions of α-smooth muscle actin and TGFβ1 both were lower in the M-VMS group than in the other 2 groups. The expression of TGFβ2 and TGFβ3 had no obvious difference among the 3 groups. For wounds under high tension, compared with SIS and VMS methods, the M-VMS technique we proposed can reduce scar formation due to the reduction of collagen formation, myofibroblast expression, and TGFβ1 expression.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Liu H, Lin MH, Jiang LL, et al. A Modified Suture Technique to Improve Scar Appearance in Wounds Under High Tension. Ann Plast Surg. 2023. PMID: 37962184. doi:10.1097/SAP.0000000000003693

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。