文献速递乳房整形与再造显微修复重建

腹壁下动脉穿支皮瓣重建术中腹腔内压围手术期升高:一项前瞻性研究并将高腹腔内压与一例患者非致死性肺栓塞相联系

Intra-abdominal pressure increases peri-operatively in patients undergoing deep inferior epigastric perforator flap reconstruction: A prospective study linking high intra-abdominal pressure to non-fatal lung embolism within one patient.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2023-10-31

前瞻性研究纳入13例接受二期腹壁下动脉穿支皮瓣乳房重建的女性,用Unometer测量膀胱内压作为腹腔内压替代指标在于腹壁皮肤关闭前、关闭后即刻及关闭后24小时。平均腹腔内压从基线6.1 mmHg升至关闭后即刻9.0 mmHg(p=0.007),24小时后升至11.7 mmHg(p=0.012)。关闭后即刻无患者腹腔内压异常(>12 mmHg),24小时后12例可评估患者中8例(67%)高于正常范围;1例发生非致死性肺栓塞。

要点

  • 腹壁下动脉穿支皮瓣重建术后平均腹腔内压显著升高,24小时达11.7 mmHg。
  • 关闭后即刻无人腹腔内压>12 mmHg,24小时后12例中8例(67%)超出正常范围。
  • 1例患者发生非致死性肺栓塞,原文将其与高腹腔内压相联系。

核心结论

  • 腹壁下动脉穿支皮瓣重建术后平均腹腔内压随围手术期显著升高,但异常腹腔内压值仅见于皮肤关闭后24小时。

研究设计与样本

  • 前瞻性研究,纳入13例接受二期腹壁下动脉穿支皮瓣乳房重建的女性,用Unometer测量膀胱内压作为腹腔内压替代指标,于基线、腹壁皮肤关闭后即刻及关闭后24小时测量。

主要发现

  • 平均腹腔内压从基线6.1 mmHg(95%CI 4.6-7.7)升至皮肤关闭后即刻9.0 mmHg(95%CI 8.0-10.0),平均差值2.9(95%CI 1.0-4.8)(p=0.007)。
  • 平均腹腔内压进一步升至关闭后24小时11.7 mmHg(95%CI 9.0-14.5),平均差值5.3(95%CI 1.4-9.1)(p=0.012)。
  • 腹腔内压存在患者间差异,与腹壁关闭的紧密度或腹直肌折叠(n=3)无关。
  • 关闭后即刻无孤立患者腹腔内压异常(>12 mmHg),而24小时后12例可评估患者中8例(67%)腹腔内压高于正常范围。
  • 1例患者发生非致死性肺栓塞。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The deep inferior epigastric perforator (DIEP) flap is the gold standard for autologous breast reconstruction. The procedure and peri-operative period are associated with the risk of severe post-operative complications, like venous thromboembolic events (VTE) and lung embolism. Whether the intra-abdominal pressure (IAP) increases after the closure of the abdominal defect, thereby potentially affecting the venous backflow and the risk of VTE, is currently not known. AIM: The primary aim is to test if the closure of the abdominal donor site increases the IAP in women undergoing secondary DIEP flap breast reconstruction. MATERIALS AND METHOD: By using a Unometer, we measured the intravesical pressure as a surrogate marker for the IAP, at baseline, immediately after, and 24 h after abdominal skin closure, for 13 patients. RESULTS: The mean IAP increased from 6.1 mmHg (95% CI 4.6-7.7) at baseline to 9.0 mmHg (95% CI 8.0-10.0) immediately after skin closure [mean diff. 2.9 (95% CI 1.0-4.8) (p = 0.007)] and further up to 11.7 mmHg (95% CI 9.0-14.5) 24 h after closure [mean diff. 5.3 (95% CI 1.4-9.1) (p = 0.012)]. We found that IAP varies among the patients, regardless of the tightness of abdominal closure or rectus plication (n = 3). Immediately after closure, none of the isolated patients showed abnormal levels of IAP (>12 mmHg), while eight out of 12 isolated patients (67%) showed IAP levels above the normal range after 24 h. One patient developed a non-fatal lung embolism. CONCLUSION: The mean IAP increases significantly over the post-operative period after DIEP flap reconstruction, although abnormal IAP values are only seen 24 h after the closure of the skin.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Warming N, Toft G, Birk-Sørensen L, et al. Intra-abdominal pressure increases peri-operatively in patients undergoing deep inferior epigastric perforator flap reconstruction: A prospective study linking high intra-abdominal pressure to non-fatal lung embolism within one patient. J Plast Reconstr Aesthet Surg. 2023. PMID: 37995521. doi:10.1016/j.bjps.2023.10.126

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。