文献速递显微修复重建创面修复

旋髂深动脉穿支嵌合皮瓣设计变异用于复合骨与软组织缺损的一期定制化重建

Variations in deep iliac circumflex artery perforator chimeric flap design for single-stage customized-reconstruction of composite bone and soft-tissue defect.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2023-10-13

研究通过12具新鲜尸体灌注氧化铅解剖旋髂深动脉(DICA)系统,并回顾2008年1月至2020年12月30例采用旋髂深动脉穿支(DICAP)嵌合皮瓣修复复合骨与软组织缺损的患者,根据缺损大小、形状和位置选用四种改良术式之一。结果发现DICA有横支与升支两种分支模式,30例皮瓣全部成活,供区均一期闭合,无转移髂骨段骨折,平均骨愈合时间5.5个月(范围4至8个月)。作者认为DICA系统适合作为DICAP嵌合皮瓣的供区来源。

要点

  • DICA存在横支与升支两种分支模式,横支发出骨肌皮穿支和终末肌皮穿支。
  • 30例DICAP嵌合皮瓣全部成活,所有患者供区均一期闭合。
  • 无患者发生转移髂骨段骨折,平均骨愈合时间5.5个月(范围4至8个月)。

核心结论

  • DICA系统是切取DICAP嵌合皮瓣重建复合骨与软组织缺损的合适来源,可为个体化覆盖此类缺损提供灵活设计且供区并发症有限。

研究设计与样本

  • 对12具新鲜尸体按标准化流程向DICA系统注射氧化铅进行解剖学研究。
  • 2008年1月至2020年12月,30例复合骨与软组织缺损患者接受DICAP嵌合皮瓣重建手术。
  • 根据缺损的大小、形状和位置,选用四种指定手术技术之一制作改良DICAP嵌合皮瓣。

主要发现

  • 观察到DICA有横支和升支两种分支模式,横支发出骨肌皮穿支和终末肌皮穿支。
  • 30例DICAP嵌合皮瓣均成功切取,皮岛大小为9×4.5 cm至22×9 cm,骨组件为3×2.5×1.5 cm至6×3.5×2 cm。
  • 所有皮瓣术后均成活,所有患者供区均一期闭合,无患者发生转移髂骨段骨折。
  • 平均骨愈合时间为5.5个月(范围4至8个月)。

临床怎么用

  • 作者认为DICA系统是切取DICAP嵌合皮瓣重建复合骨与软组织缺损的合适来源,可提供灵活设计以个体化覆盖此类缺损且供区并发症有限。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The deep iliac circumflex artery (DICA) perforator (DICAP) chimeric flap is a valuable treatment strategy for single-stage reconstruction of composite bone and soft-tissue defects in upper and lower extremities. However, its utilization rate remains low owing to anatomical variations that lead to challenges when identifying and dissecting perforators. METHODS: A comprehensive anatomical investigation was conducted on the DICA system by injecting lead oxide into 12 fresh cadavers following a standardized procedure. From January 2008 to December 2020, 30 patients with composite bone and soft-tissue defects received reconstruction surgery with DICAP chimeric flap. One of the four specified surgical techniques was used to create a modified DICAP chimeric flap for the patients based on the size, shape, and location of the defect. RESULTS: Two branching patterns of DICA, transverse and ascending branches, were observed, and the former gave off the osteomusculocutaneous perforators and terminal musculocutaneous perforators. Thirty DICAP chimeric flaps were elevated successfully. The size of the skin paddles measured from 9 × 4.5 cm to 22 × 9 cm, and the bone components ranged from 3 × 2.5 × 1.5 cm to 6 × 3.5 × 2 cm. All flaps survived successfully after the operation, and all patients achieved primary closure of the donor sites. No patient encountered the fracture of transferred iliac segments. The mean bone union time was 5.5 months (ranging from 4 to 8 months). CONCLUSION: The DICA system is a suitable source for harvesting the DICAP chimeric flap to reconstruct composite bone and soft-tissue defects. It provides a flexible design for individualized coverage of such defects with limited donor-site morbidity.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Qing L, Luo G, et al. Variations in deep iliac circumflex artery perforator chimeric flap design for single-stage customized-reconstruction of composite bone and soft-tissue defect. J Plast Reconstr Aesthet Surg. 2023. PMID: 37924718. doi:10.1016/j.bjps.2023.10.050

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。