旋髂浅动脉穿支皮瓣的静脉解剖:尸体与临床研究
通过8侧尸体腹股沟静脉染料注射与解剖,并结合2015年4月至2019年12月102例旋髂浅动脉穿支皮瓣重建的临床资料,研究该皮瓣的静脉引流解剖。结果发现旋髂浅静脉为独立引流系统,与伴行静脉之间存在摆动连接,旋髂浅静脉直径约为伴行静脉的两倍;仅以旋髂浅静脉引流时,皮瓣丢失率与静脉淤血率与伴行静脉引流或双引流相比无显著差异。作者认为,旋髂浅动脉穿支皮瓣采用单动脉与旋髂浅静脉吻合的静脉淤血率低,术者应考虑使用旋髂浅静脉进行安全的皮瓣重建。
要点
- 旋髂浅静脉是独立引流系统,与伴行静脉间存在摆动连接。
- 旋髂浅静脉直径约为伴行静脉的两倍,两者血管网面积提示共同优势。
- 仅旋髂浅静脉引流时,皮瓣丢失率和静脉淤血率与伴行静脉或双引流相比无显著差异。
核心结论
- 旋髂浅动脉穿支皮瓣采用单动脉与旋髂浅静脉吻合,静脉淤血率低;术者应考虑使用旋髂浅静脉进行安全的皮瓣重建。
研究设计与样本
- 尸体解剖研究:8侧尸体腹股沟行静脉染料注射与解剖,识别旋髂浅静脉和伴行静脉血管网并研究优势引流。
- 临床研究:2015年4月至2019年12月共行102例旋髂浅动脉穿支皮瓣重建,主要使用旋髂浅动脉的浅支,分析临床资料并与尸体解剖结果关联。
- 皮瓣按静脉引流分为三组:I组为双引流(伴行静脉和旋髂浅静脉),II组为仅旋髂浅静脉,III组为仅伴行静脉。
主要发现
- 临床病例与尸体解剖结果关联显示,旋髂浅静脉是独立引流系统,与伴行静脉之间存在摆动连接。
- 旋髂浅静脉直径约为伴行静脉的两倍,各血管网面积提示两者共同优势。
- 与伴行静脉引流或双引流相比,仅以旋髂浅静脉作为单一引流时,皮瓣丢失率或静脉淤血率无显著差异。
临床怎么用
- 作者认为,旋髂浅动脉穿支皮瓣采用单动脉与旋髂浅静脉吻合的静脉淤血率低,术者应考虑使用旋髂浅静脉进行安全的皮瓣重建。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Reconstructive surgeons frequently face challenges with free tissue transfer when transplanted flaps are thicker than intended. This is especially pronounced in lower limb cases, where the soft tissue below the knee is thin. The supra-fascial superficial circumflex iliac perforator (SCIP) flap overcomes this problem, but venous congestion remains a concern. We aim to examine the venous anatomy of the SCIP flap through cadaveric dissections and clinical data analyses to enhance the understanding of the venous anatomy and reduce venous congestion in future procedures. METHODS: Eight cadaveric groins underwent venous dye injection and dissection to identify the superficial circumflex iliac vein (SCIV) and venae comitantes (VC) vascular networks. The venous anatomy was studied for dominant drainage. From April 2015 to December 2019, we conducted 102 SCIP flap reconstructions, mainly using the superficial circumflex iliac artery's superficial branch. Clinical data were analyzed and correlated with cadaveric dissections. SCIP flaps were categorized into three groups: dual drainage (VC and SCIV) in group I, SCIV-only in group II, and VC-only in group III. RESULTS: Correlations between clinical cases and cadaveric dissections revealed the SCIV as an independent drainage system with oscillating links to the VC. The SCIV is approximately twice the diameter of the VC, and the area of each vascular network suggests codominance. No significant difference in flap loss or venous congestion rates was noted when SCIV was the sole drainage, compared with VC or dual drainage. CONCLUSION: The SCIP flap with one artery and SCIV anastomosis, exhibits low venous congestion rates. Surgeons should consider SCIV for safe SCIP flap reconstruction.
引用
- Sun JM, Yamamoto T, Goh TL, et al. Venous anatomy of the superficial circumflex iliac artery perforator flap: A cadaveric and clinical study. J Plast Reconstr Aesthet Surg. 2023. PMID: 37948880. doi:10.1016/j.bjps.2023.10.096
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。