PubMed 文献 · J Plast Reconstr Aesthet Surg · 2023-07-21

本回顾性队列研究评估乳腺癌患者行皮下乳房切除联合假体即刻乳房再造时使用3DMax™补片或TIGR® Matrix Surgical Mesh的术后并发症。研究涉及82例患者的乳房再造手术,其中3D补片组57例手术、TIGR补片组49例手术;两组在年龄、体质指数、癌症分期或手术并发症方面无显著差异;接受新辅助化疗或放疗的患者远期并发症发生率高于其他患者;发生感染或部分坏死的患者假体丢失风险升高;作者认为在即刻乳房再造使用的合成补片中,3DMax™在并发症方面不劣于TIGR Matrix Surgical Mesh。

要点

  • 3DMax™补片组57例手术与TIGR补片组49例手术在年龄、体质指数、癌症分期及手术并发症方面无显著差异。
  • 接受新辅助化疗或放疗的患者远期并发症发生率高于其他患者。
  • 发生感染或部分坏死的患者假体丢失风险升高。

核心结论

  • 作者认为,在即刻乳房再造使用的合成补片中,3DMax™在并发症方面不劣于TIGR Matrix Surgical Mesh。

研究设计与样本

  • 回顾性队列研究,评估乳腺癌患者行皮下乳房切除联合硅胶假体即刻乳房再造使用3DMax™补片或TIGR® Matrix Surgical Mesh的术后并发症。
  • 研究涉及82例患者的乳房再造手术,其中3D补片组57例手术,TIGR补片组49例手术。

主要发现

  • 3D补片组57例手术与TIGR补片组49例手术在年龄、体质指数(BMI)、癌症分期或手术并发症方面无显著差异。
  • 接受新辅助化疗或放疗的患者远期并发症发生率高于其他患者。
  • 发生感染或部分坏死的患者假体丢失风险升高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Breast reconstruction (BR) surgery is a widely utilized approach for women who have undergone mastectomy. Using synthetic mesh can offer advantages over other materials providing long-lasting support and natural-looking results. This study aims to compare the effectiveness of 3DMax™ mesh to TIGR mesh in BR surgery, providing clear information about the non-inferiority of 3DMax™ mesh to TIGR. METHODS: This retrospective cohort study evaluates postoperative complications in breast cancer patients who underwent subcutaneous mastectomy with direct-to-implant immediate BR using silicone implants and either 3DMax™ mesh or TIGR® Matrix Surgical Mesh. RESULTS: This study involved BR surgeries in 82 patients, including 57 surgeries in the 3D mesh group and 49 in the TIGR mesh group. The two groups had no significant differences regarding age, body mass index (BMI), cancer stage, or surgical complications. However, patients with neoadjuvant chemotherapy or radiotherapy had higher incidence rates of long-term complications than other patients. Patients with infection or partial necrosis had a heightened risk of implant loss. CONCLUSION: The clinical results obtained in this study suggest that among synthetic meshes used in immediate BR, 3DMax™ is not inferior to TIGR Matrix Surgical Mesh regarding complications.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Karoobi M, Yazd SMM, Nafissi N, et al. Comparative clinical outcomes of using three-dimensional and TIGR mesh in immediate breast reconstruction surgery for breast cancer patients. J Plast Reconstr Aesthet Surg. 2023. PMID: 37826925. doi:10.1016/j.bjps.2023.07.038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。