组织血氧测定与传统方法用于自体乳房再造术后监测的系统综述与Meta分析更新
该系统综述与Meta分析纳入3项回顾性队列研究,比较组织血氧测定与传统方法在自体乳房再造术后监测中的效果,共涉及组织血氧测定组1644个皮瓣和对照组1387个皮瓣。结果显示两种技术在任何测量结局上均无优势,各结局的估计均值差异均未达统计学显著。
要点
- 组织血氧测定与传统监测在早期重返手术室、皮瓣部分或完全丢失及晚期脂肪坏死上均无优势。
- 纳入3项回顾性队列研究,组织血氧测定组1644个皮瓣,对照组1387个皮瓣。
- 作者认为需将前瞻性研究和随机试验纳入现有文献。
核心结论
- 在混合时间线回顾性队列研究的系统综述与Meta分析中,组织血氧测定并未提供更优的患者结局,改变了当前对乳房再造术后监测的理解。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Embase和Web of Science,最终纳入3项回顾性队列研究。
- 组织血氧测定组共1644个皮瓣,对照组共1387个皮瓣。
- 1项研究中组织血氧测定为较早队列,2项研究中组织血氧测定为较晚队列。
主要发现
- 早期重返手术室的估计均值差异为-0.06(95%CI -0.52至0.410;P=0.82)。
- 皮瓣部分丢失的估计均值差异为-0.04(95%CI -0.86至0.79;P=0.93)。
- 皮瓣完全丢失的估计均值差异为-1.29(95%CI -3.45至0.87;P=0.24)。
- 晚期脂肪坏死的估计均值差异为-0.02(95%CI -0.42至0.39;P=0.94)。
局限性
- 作者指出需将比较监测方法的前瞻性研究和随机试验纳入现有文献。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Tissue oximetry monitoring has shown superior outcomes to conventional monitoring methods for autologous breast reconstruction in retrospective studies with consecutive cohorts. A recent study used consecutive cohorts with tissue oximetry as the earlier cohort and found that tissue oximetry was nonsuperior. We hypothesize that improvement in microsurgical outcomes with institutional experience confounds the superiority of tissue oximetry demonstrated in prior studies. This study aimed to perform a systematic review and meta-analysis of the outcomes of tissue oximetry monitoring compared with conventional monitoring. METHODS: Relevant studies were found using PubMed, Embase, and Web of Science searches for keywords such as near-infrared spectroscopy or tissue oximetry and microsurgery. Studies included compared tissue oximetry and conventional monitoring in autologous breast reconstruction patients. Studies were excluded if they did not contain a comparison group. Random-effective models were used to analyze early returns to the operating room, the total number of partial or complete flap loss, and late fat necrosis. RESULTS: Six hundred sixty-nine studies were identified; 3 retrospective cohort studies met the inclusion criteria. A total of 1644 flaps were in the tissue oximetry cohort, and 1387 flaps were in the control cohort. One study contained tissue oximetry as the former cohort; 2 had tissue oximetry as the latter. Neither technique was superior for any measured outcomes. The estimated mean differences between tissue oximetry and conventional monitoring method were early returns, -0.06 (95% confidence interval [CI], -0.52 to 0.410; P = 0.82); partial flap loss, -0.04 (95% CI, -0.86 to 0.79; P = 0.93); complete flap loss, -1.29 (95% CI, -3.45 to 0.87; P = 0.24); and late fat necrosis -0.02 (95% CI, -0.42 to, 0.39; P = 0.94). CONCLUSIONS: In a systematic review and meta-analysis of mixed timeline retrospective cohort studies, tissue oximetry does not provide superior patient outcomes and shifts our current understanding of postoperative breast reconstruction monitoring. Prospective studies and randomized trials comparing monitoring methods need to be included in the existing literature.
引用
- Johnson BM, Egan KG, He J, et al. An Updated Systematic Review and Meta-Analysis of Tissue Oximetry Versus Conventional Methods for Postoperative Monitoring of Autologous Breast Reconstruction. Ann Plast Surg. 2023. PMID: 37823627. doi:10.1097/SAP.0000000000003705
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。