术后游离皮瓣监测的辅助技术:系统综述
该系统综述纳入22项研究、6370个皮瓣,评估多种辅助监测技术对微血管危象的检测效能。Cook Swartz多普勒和 tissue oximetry 与快速识别危象及重返手术室相关,其他技术显示前景,但需进一步随机对照试验进行头对头比较。
要点
- Cook Swartz多普勒监测1391个皮瓣,真阳性率80.17%,挽救率83.63%,总皮瓣失败率2.60%。
- Tissue oximetry监测1417个皮瓣,真阳性率74.76%,挽救率88.62%。
- 激光多普勒、双功超声、光光谱和Synovis流量耦合器真阳性率69.4%至100%,挽救率64%至100%。
核心结论
- Cook Swartz多普勒和tissue oximetry与快速识别微血管危象及重返手术室相关。
- 近红外光谱、激光多普勒和双功超声等替代方式显示前景。
- 需进一步设计良好的随机对照试验进行头对头效能比较。
研究设计与样本
- 系统综述,纳入22项研究,共6370个皮瓣。
主要发现
- 重返手术皮瓣中微血管危象总体真阳性率为70.18%。
- Cook Swartz多普勒监测1391个皮瓣,真阳性率80.17%,挽救率83.63%,总皮瓣失败率2.60%。
- Tissue oximetry监测1417个皮瓣,真阳性率74.76%,挽救率88.62%。
- 激光多普勒、双功超声、光光谱和Synovis流量耦合器真阳性率在69.4%至100%之间,挽救率在64%至100%之间。
临床怎么用
- 原文未据此给出推荐。
局限性
- 需进一步设计良好的随机对照试验进行头对头效能比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Patent microvascular anastomoses are essential for successful free tissue transfer. Early accurate detection of microvascular compromise is required for flap salvage. Adjunctive monitoring techniques, in addition to clinical examination, are increasingly used to detect flap compromise. This systematic review synthesized and appraised the literature to determine the efficacy of different postoperative monitoring technologies. Rates of flap takeback, salvage, failure, and mean time to detection of microvascular compromise were extracted, synthesized, and reviewed. Twenty-two studies were included, comprising 6370 flaps. One thousand three hundred and ninety-five flaps were monitored with Cook Swartz Doppler (21.83%), 1417 flaps with tissue oximetry (22.24%), 291 with laser Doppler (4.56%), 175 with duplex echography (2.74%), 210 with indocyanine green (ICG) fluorescence (3.30%), 196 with Synovis flow coupler (3.07%), and 81 (1.27%) with light spectroscopy. The overall true positive rate for microvascular compromise in taken back flaps was 70.18%. Cook Swartz Doppler (n = 1391) had a true positive rate of 80.17% and 83.63% salvage rate and was associated with an overall 2.60% rate of flap failure. Tissue oximetry (n = 1417) had a true positive rate of 74.76% and a salvage rate of 88.62%. Laser Doppler, duplex echography, light spectroscopy, and Synovis flow coupler demonstrated true positive rates between 69.4% and 100% with salvage rates between 64% and 100%. Cook Swartz Doppler and tissue oximetry are associated with prompt identification of microvascular compromise and return to theatre. Alternative modalities, including near-infrared spectroscopy, laser Doppler, and duplex echography, show promise. Further well-designed randomised controlled trials (RCTs) appraising head-to-head efficacy are required to comparatively assess adjunctive technologies.
引用
- Lacey H, Kanakopoulos D, Hussein S, et al. Adjunctive technologies in postoperative free-flap monitoring: a systematic review. J Plast Reconstr Aesthet Surg. 2023. PMID: 37844383. doi:10.1016/j.bjps.2023.09.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。