经脐硅胶假体隆乳术
该研究回顾性分析了2016年6月至2021年4月接受经脐硅胶假体隆乳术(TUSBA)的74例患者,评估使用多种预充式硅胶假体及不同剥离平面的可行性。早期采用内镜辅助钝性剥离,后期转为全内镜剥离。结果显示该术式可行且适用所有剥离平面,全内镜技术有助于降低较高的并发症率。证据等级为治疗性IV级。
要点
- TUSBA使用多种预充式硅胶假体(表面光滑、纹理或纳米纹理,圆形或解剖形,最大500 mL)可行,适用于腺下、筋膜下及双平面植入。
- 内镜辅助组3例(4.6%)需重大修复手术,全内镜组无修复病例。
- 全内镜技术有助于降低较高的并发症率。
核心结论
- TUSBA使用多种类型硅胶假体可行且适用于所有剥离平面,全内镜技术有助于降低较高的并发症率。
研究设计与样本
- 回顾性分析2016年6月至2021年4月接受TUSBA的74例患者,平均年龄36.4岁(范围21至55岁),随访1个月至4.5年(平均15.6个月)。
- 早期阶段主要采用内镜辅助钝性剥离,后期转为全内镜剥离;两组均使用内镜确认腔隙并检查出血。
主要发现
- 内镜辅助组3例(4.6%)需重大修复手术,全内镜组无修复病例。
- 两组术后均无乳房或腹部过度疼痛报告,手术效果在美学上均令人满意。
关键数值与推荐
- 使用假体表面为光滑、纹理或纳米纹理,形状为圆形或解剖形,尺寸最大500 mL。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
SUMMARY: In transumbilical breast augmentation (TUBA) with prefilled silicone implants, technical challenges remain to accommodate more implant options and dissection planes. The authors aimed to demonstrate the feasibility of TUBA using various types of prefilled silicone implants (TUSBA) and its applicability for subglandular, subfascial, dual-plane implantation. In the early stage, TUSBA was primarily performed using endoscope-assisted blunt dissection, and later converted to full endoscopy dissection to achieve better results. An endoscope was used to confirm the pocket and check bleeding for both groups. For the endoscope-assisted group, surgical techniques were modified from conventional TUBA. In full endoscopy TUSBA, the entire dissection process was performed under endoscopic monitoring. Preliminary data of patients undergoing TUSBA from June of 2016 to April of 2021 were retrospectively reviewed. Breast implants with smooth, textured, or nanotextured surface properties and round or anatomic shapes were used, with sizes up to 500 mL. Seventy-four patients with a mean age of 36.4 years (range, 21 to 55 years) were enrolled in this study. Follow-up ranged from 1 month to 4.5 years (mean, 15.6 months). No excessive postoperative pain in breast or abdomen was reported. Surgery outcomes were aesthetically pleasing in both groups. In the endoscope-assisted group, 3 patients (4.6%) required major revisional procedures. No revision was required in the full-endoscopy group. TUSBA with various types of silicone implants is feasible and accommodable to all dissection planes. The full-endoscopy technique is helpful in reducing the higher complication rate. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- Huang WC, Tsai MF, Yang ST, et al. Transumbilical Silicone Implant Breast Augmentation. Plast Reconstr Surg. 2023. PMID: 37506358. doi:10.1097/PRS.0000000000010946
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。