文献速递创面修复烧伤

皮肤替代物的氧透过率与移植物存活

Oxygen transmission rates of skin substitutes and graft survival.
PubMed 文献 · Burns · 2023-05-22

本研究在互连封闭系统中比较土耳其市售的Nevelia®、MatriDerm®和Pelnac®三种真皮基质在侧向平面上的氧通透性,通过铁与氧反应的颜色变化评估氧传输长度,并记录电子显微图像比较操作前后变形。结果显示三者氮侧氧率分别为29%、34%和27%,侧向氧传输长度分别为1、2和0.5 cm;MatriDerm®被确定为无血管区域最适合的支架。

要点

  • MatriDerm®侧向氧传输长度2 cm,为三种支架中最长。
  • Pelnac®侧向氧传输长度0.5 cm,且有轻微变形。
  • 三种支架操作后均保持支架特性,无明显变形。

核心结论

  • 三种支架均无明显变形且操作后均保持支架特性,MatriDerm®因侧向氧传输长度达2 cm而被确定为无血管区域最适合的支架。

研究设计与样本

  • 体外实验:在互连封闭系统中比较土耳其市售的Nevelia®、MatriDerm®和Pelnac®三种真皮基质的氧通透性,以铁与氧反应所致颜色变化评估氧传输,并记录电子显微图像比较操作前后变形。

主要发现

  • 两种支架操作后无变形,而Pelnac®有轻微变形。
  • 测试装置氮侧的氧率:Nevelia®为29%,MatriDerm®为34%,Pelnac®为27%。
  • 侧向平面氧传输长度(颜色变化长度):Nevelia®为1 cm,MatriDerm®为2 cm,Pelnac®为0.5 cm。

临床怎么用

  • 作者认为MatriDerm®是用于无血管区域最适合的支架,依据为其侧向氧传输长度为2 cm。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: Oxygen is required for cell migration into the scaffold and for the survival of the overlying graft in the use of a single-layer scaffold. In the absence of diffusion from the avascular wound base, such as in areas above the bone/tendon, oxygen delivery from the lateral edges of the scaffold is important. This study compared the oxygen permeability of skin scaffolds, currently commercially available in Turkey (Nevelia®, MatriDerm®, and Pelnac®), in the lateral plane. MATERIALS AND METHODS: To measure oxygen permeability, an interconnected closed system was created. Oxygen permeability was evaluated based on the color change that occurred as a result of the reaction of iron with oxygen. After the dermal matrices placed in the closed system were exposed to oxygen, the color change on the surface of the dermal matrices was measured, and electron microscopic images were recorded to compare deformation before and after the procedure. RESULTS: Two scaffolds did not show deformation after the procedure while Pelnac® had minimal deformation. The oxygen rates on the nitrogen side of the test apparatus were found to be 29%, 34%, and 27% for Nevelia®, MatriDerm®, and Pelnac®, respectively; and the oxygen transmission lengths (length of color change) of these scaffolds in the lateral plane were 1, 2, and 0.5 cm, respectively. CONCLUSION: Although none of the scaffolds showed significant deformation, and all continued to exhibit their scaffold properties after the procedure, MatriDerm® was determined to be the most suitable scaffold for use in avascular areas, with a 2-cm oxygen transmission length in terms of lateral oxygenation.

来源:Burns,查看原文。版权归原作者所有。

引用

  1. Yasti AÇ, Çolak B, Özcan F, et al. Oxygen transmission rates of skin substitutes and graft survival. Burns. 2023. PMID: 37280139. doi:10.1016/j.burns.2023.05.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。