贯通性口下颌缺损的总表面积与单一腓骨游离皮瓣重建术后血栓栓塞事件相关
该回顾性队列研究纳入2011至2020年一家三级医疗中心43例接受单一腓骨游离皮瓣重建贯通性复合口下颌缺损的患者,比较发生与未发生血栓栓塞事件两组。骨缺损长度和总表面积在两组间差异有统计学意义,总表面积为血栓栓塞事件的独立预测因素,判定阈值为159 cm²。
要点
- 骨缺损长度在无血栓栓塞事件组为6.70±1.95,血栓栓塞事件组为9.04±2.96(P=0.004)。
- 总表面积在无血栓栓塞事件组为105.99±60.33,血栓栓塞事件组为169.38±41.21(P=0.004)。
- 总表面积判定血栓栓塞事件的阈值为159 cm²(P=0.005;敏感度75%,特异度82.9%;95%CI 0.684-0.952)。
核心结论
- 总表面积较大的贯通性复合口下颌缺损采用单一腓骨游离皮瓣重建时血栓栓塞事件风险升高,总表面积可作为客观参考指标。
研究设计与样本
- 回顾性队列研究,纳入2011至2020年一家三级医疗中心接受单一腓骨游离皮瓣重建贯通性复合口下颌缺损的43例连续患者。
主要发现
- 43例中无血栓栓塞事件组35例,血栓栓塞事件组8例;8例发生血栓栓塞事件者均未能挽救。
- 年龄、体重指数、吸烟、高血压、糖尿病和放疗史在两组间无显著差异。
- 骨缺损长度无血栓栓塞事件组6.70±1.95 vs 血栓栓塞事件组9.04±2.96(P=0.004)。
- 总表面积无血栓栓塞事件组105.99±60.33 vs 血栓栓塞事件组169.38±41.21(P=0.004)。
- 总表面积在单因素 logistic 回归中与血栓栓塞事件相关(P=0.020;OR=1.02;95%CI 1.003-1.033),调整混杂因素后多因素分析仍相关(P=0.033;OR=1.026;95%CI 1.002-1.051)。
关键数值与推荐
- 总表面积判定血栓栓塞事件的阈值为159 cm²(P=0.005;敏感度75%,特异度82.9%;95%CI 0.684-0.952)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Reconstruction of through-and-through composite oromandibular defects (COMDs) has been a challenge to plastic surgeons for decades. When using a free osteoseptocutaneous fibular flap, the skin paddle is restricted by the orientation of the peroneal vessels and the inset of bone segment(s). Although the combination of double flaps for extensive COMDs is viable and reliable, the decision of single- or double-flap reconstruction is still debated, and the risk factors leading to complications and flap failure of single-flap reconstruction are less discussed. AIM AND OBJECTIVES: The aim of this study was to determine objectively predictive factors for postoperative vascular complications in through-and-through COMDs reconstructed with a single fibula flap. METHODS: This was a retrospective cohort study in patients who underwent single free fibular flap reconstruction for through-and-through COMDs in a tertiary medical center from 2011 to 2020. The enrolled patients' characteristics, surgical methods, thromboembolic event, flap outcomes, intensive care unit care, and total hospital length of stay were analyzed. RESULTS: A total of 43 consecutive patients were included in this study. Patients were categorized into a group without thromboembolic events (n = 35) and a group with thromboembolic events (n = 8). The 8 subjects with thromboembolic events were failed to be salvaged. There was no significant difference in age, body mass index, smoking, hypertension, diabetes mellitus, and history of radiotherapy. The length of bony defect (6.70 ± 1.95 vs 9.04 ± 2.96, P = 0.004) and the total surface area (105.99 ± 60.33 vs 169.38 ± 41.21, P = 0.004) were the 2 factors that showed a significant difference between the groups. Total surface area was the only significant factor in univariate logistic regression for thromboembolic event (P = 0.020; odds ratio, 1.02; 95% confidence interval [CI], 1.003-1.033) and also in multivariate logistic regression analysis after adjusting confounding factors (P = 0.033; odds ratio, 1.026; 95% CI, 1.002-1.051).The cutoff level of total surface area in determining thromboembolic event development was 159 cm2 (P = 0.005; sensitivity of 75% and specificity of 82.9%; 95% CI, 0.684-0.952). CONCLUSIONS: Free fibula flap has its advantages and drawbacks on mandible restoration. Because there is a lack of indicators before, a large total surface area may be an objective reference for single-flap reconstruction of through-and-through COMDs due to an elevated risk of thromboembolic event.
引用
- Chen CE, Ma CY, Wang TH, et al. Total Surface Area of a Through-and-Through Oromandibular Defect Is Associated With Thromboembolic Events for Reconstruction With a Single Fibula Free Flap. Ann Plast Surg. 2023. PMID: 37075292. doi:10.1097/SAP.0000000000003348
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。