文献速递乳房整形与再造美容整形

新一代光面假体混合法乳房增大提升术:结合脂肪移植、下极肌肉支撑与L形瘢痕的优势

Hybrid Augmentation Mastopexy with New Generation of Smooth Surface Implants: Combining the Benefits of Fat Grafting, Inferior Muscle Support, and an L-Shaped Scar.
PubMed 文献 · Plast Reconstr Surg · 2023-06-29

45例患者(90侧乳房)接受复合反向下极肌肉吊带联合自体脂肪移植的混合法乳房增大提升术,平均假体体积265 cc,术后1年内下极拉伸约9.8%–11.51%,胸间距平均减少49.9%,3例患者出现5项并发症(6.6%)。作者认为该术式对乳房下垂且软组织覆盖差的患者改善了美学效果,是乳房增大提升术的良好替代方案。

要点

  • 复合反向下极肌肉吊带联合脂肪移植用于乳房增大提升术,平均假体体积265 cc。
  • 术后10天至1年下极拉伸右侧11.51%(9.9 mm)、左侧9.8%(8.5 mm),P<0.0001。
  • 胸间距术前至术后1年平均减少49.9%(25.1 mm),P<0.001。

核心结论

  • 作者认为混合复合反向下极肌肉吊带改善了乳房下垂且软组织覆盖差患者的美学效果。
  • 作者指出脂肪移植和识别乳房分界区对获得满意结果仍很重要。
  • 作者认为该术式为乳房增大提升术候选者提供了良好替代方案,为假体稳定提供足够的光面。

研究设计与样本

  • 45例患者(90侧乳房;平均年龄37.7±7.2岁)接受混合复合反向下极肌肉吊带乳房增大提升术。
  • 在假体与锁骨区及胸骨旁区之间的上/内侧极区域标记接受脂肪移植,并分为三个区域。
  • 使用三维成像评估下极拉伸和胸间距。

主要发现

  • 平均假体体积为265 cc(范围175至335 cc)。
  • I/II区和III区平均脂肪体积分别为80.1 cc(范围61.6至95.2 cc)和39.3 cc(范围25.2至47.3 cc)。
  • 3例患者(6.6%)出现5项并发症:2例(4.4%)轻微裂开,1例(2.2%)乳头乳晕不对称。
  • 术后10天至1年下极拉伸右侧为11.51%(9.9 mm)、左侧为9.8%(8.5 mm),P<0.0001。
  • 胸间距术前至术后1年平均减少49.9%(25.1 mm),P<0.001。

临床怎么用

  • 作者认为该术式可为乳房增大提升术候选者提供良好替代方案,并为假体稳定提供足够的光面。
  • 作者指出脂肪移植和识别乳房分界区对获得满意结果仍很重要。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Augmentation mastopexy (AM) is a challenging procedure. Complications include implant displacement and visibility, which can be addressed, but the stability of the smooth implant surface and poor soft-tissue coverage may present limitations. This article describes a surgical technique for AM using a composite reverse inferior muscle sling associated with autogenous fat grafting. METHODS: Forty-five patients (90 breasts; mean age, 37.7 ± 7.2 years) underwent hybrid composite reverse inferior muscular sling AM. An upper/medial pole area between the implant and the clavicle region and parasternal area was marked to receive fat grafting and divided into three zones. Three-dimensional imaging was used to evaluate lower pole stretch and intermammary distance. RESULTS: The average implant volume was 265 cc (range, 175 to 335 cc). The average fat volumes in zones I/II and III were 80.1 (range, 61.6 to 95.2 cc) and 39.3 (range, 25.2 to 47.3 cc), respectively. Five complications were observed in three patients (6.6%)-minor dehiscence in two (4.4%) and nipple-areola asymmetry in one (2.2%). The lower pole stretched 11.51% (9.9 mm) and 9.8% (8.5 mm) on the right and left sides, respectively ( P < 0.0001), between 10 days and 1 year postoperatively. The intermammary distance was reduced, on average, 49.9% (25.1 mm) ( P < 0.001) between the preoperative value and 1 year postoperatively. CONCLUSIONS: Hybrid composite reverse inferior muscular sling has led to improved aesthetic results for patients with breast ptosis and poor tissue coverage. Fat grafting and recognizing cleavage zones are still important to obtain satisfactory results. This procedure offers a good alternative for AM candidates, providing an adequate smooth surface for implant stabilization.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Munhoz AM, Marques Neto AA, Maximiliano J, et al. Hybrid Augmentation Mastopexy with New Generation of Smooth Surface Implants: Combining the Benefits of Fat Grafting, Inferior Muscle Support, and an L-Shaped Scar. Plast Reconstr Surg. 2023. PMID: 36728268. doi:10.1097/PRS.0000000000010196

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。