鼻中隔延伸移植物在初次鼻整形术中优于鼻小柱支撑移植物:改善长期鼻尖稳定性
本研究回顾性比较了鼻中隔延伸移植物与鼻小柱支撑移植物在初次开放鼻整形术中的长期稳定性。结果显示,鼻小柱支撑组1年鼻尖突出度丢失4.7%,鼻中隔延伸移植物组仅0.2%(P<0.0001);旋转度丢失分别为4.9度与1.3度(P<0.0001)。鼻中隔延伸移植物几乎无突出度丢失,旋转丢失轻微。
要点
- 鼻中隔延伸移植物组1年鼻尖突出度丢失0.2%,鼻小柱支撑组丢失4.7%(P<0.0001)。
- 鼻小柱支撑组旋转度丢失4.9度,鼻中隔延伸移植物组丢失1.3度(P<0.0001)。
- 使用鼻小柱支撑时,突出度丢失>4%的风险增加5.1倍(P<0.005)。
核心结论
- 鼻中隔延伸移植物几乎无鼻尖突出度丢失,旋转丢失轻微;单独使用鼻小柱支撑可预期出现小程度的突出度和旋转丢失。
研究设计与样本
- 回顾性综述,纳入2016年至2019年由资深作者(R.J.R.)施行的所有初次鼻整形术,纳入随访至少1年的成人初次开放鼻整形患者,排除修复病例及使用肋软骨移植者。
- 图表查询共获得133例患者,其中40例使用鼻小柱支撑,37例使用鼻中隔延伸移植物。
主要发现
- 1年时鼻尖突出度丢失:鼻小柱支撑组4.7% vs 鼻中隔延伸移植物组0.2%(P<0.0001)。
- 多变量逻辑回归显示,使用鼻小柱支撑时突出度丢失>4%的风险增加5.1倍(P<0.005)。
- 平均旋转度丢失:鼻小柱支撑组4.9度 vs 鼻中隔延伸移植物组1.3度(P<0.0001)。
- 鼻小柱支撑的独立效应导致旋转丢失≥5度的风险增加2.8倍(P<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Columellar strut grafts and septal extension grafts are commonly used support structures; however, their relative effectiveness remains debated. The purpose of this study was to compare the long-term stability of septal extension grafts to that of columellar strut grafts. METHODS: A retrospective review of all primary rhinoplasties performed by the senior author (R.J.R.) from 2016 to 2019 was performed. All adult patients undergoing primary open rhinoplasty with at least 1 year of follow-up were included. Revision cases and those in whom rib grafts were used were excluded. Standardized postoperative imaging was assessed at 2 months (early) and at 12 months (long-term) to measure projection/rotation change over time. Univariate and multivariable statistical comparisons were performed. RESULTS: The chart query yielded 133 patients. Of these, 40 patients were treated with a columellar strut and 37 patients were treated with a septal extension graft. Projection loss at 1 year was 4.7% for the columellar strut group compared with 0.2% for the septal extension graft group ( P < 0.0001). On multivariable logistic regression, there was a 5.1-fold increased risk of greater than 4% projection loss when using a columellar strut ( P < 0.005). Mean rotation loss for the columellar strut group was 4.9 degrees compared with 1.3 degrees for the septal extension graft group ( P < 0.0001). The independent effect of columellar strut use resulted in a 2.8-fold increased risk of rotation loss greater than or equal to 5 degrees ( P < 0.05). CONCLUSIONS: Septal extension grafts result in effectively no loss of projection and minimal loss in rotation. A small degree of projection and rotation loss can be expected with the use of a columellar strut alone. These long-term graft tendencies should be anticipated and accounted for appropriately. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, III.
引用
- Bellamy JL, Rohrich RJ. Superiority of the Septal Extension Graft over the Columellar Strut Graft in Primary Rhinoplasty: Improved Long-Term Tip Stability. Plast Reconstr Surg. 2023. PMID: 36728586. doi:10.1097/PRS.0000000000010147
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。