旋转腹部皮瓣:一种治疗和避免乳房增大术后下极轮廓畸形的新简单技术
该回顾性研究纳入两组患者:A组25例乳房增大术后出现可见双轮廓畸形者,B组22例下极缩窄且乳头至乳房下皱襞距离短的初次增大者;采用以头侧为蒂的腹部脂肪瓣铰链旋转上移增加下极厚度。A组25例中22例效果良好,2例双侧、1例单侧矫正不足,1例脂肪坏死团块无需治疗;B组无患者出现明显双轮廓畸形,1例单侧内侧乳房极体积过多,1例术后血肿4周内自行吸收。
要点
- 旋转腹部脂肪瓣可增加新旧乳房下皱襞之间下极区域的厚度,治疗双轮廓畸形。
- A组25例中22例效果良好,2例双侧、1例单侧矫正不足,1例脂肪坏死团块未需治疗。
- B组22例初次增大者无患者出现明显双轮廓畸形,1例单侧内侧乳房极体积过多,1例术后血肿4周内吸收。
核心结论
- 许多患者双轮廓畸形的发生与自然乳房皱襞上下区域厚度差异有关。
- 旋转腹部脂肪瓣增加新旧乳房下皱襞之间缺乏体积的下极区域厚度,从而治疗许多患者的双轮廓畸形。
- 同一技术可用于乳头至乳房下皱襞距离短或乳房紧的初次增大患者,以避免双轮廓畸形风险。
研究设计与样本
- 回顾性研究,比较两组患者。
- A组25例乳房增大术后出现可见双轮廓畸形。
- B组22例下极缩窄且乳头至乳房下皱襞距离短的初次乳房增大患者。
- 技术为利用以头侧为蒂的腹部脂肪瓣,铰链旋转上移。
主要发现
- A组25例中22例效果良好,2例双侧和1例单侧矫正不足,1例脂肪坏死团块无需治疗。
- B组无患者出现明显双轮廓畸形,1例单侧内侧乳房极体积过多,1例术后血肿4周内吸收。
关键数值与推荐
- 双轮廓畸形多见于乳头至乳房下皱襞距离短或乳房紧的患者。
- 自然乳房皱襞上下区域厚度差异与双轮廓畸形发生相关。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Double-contour deformity represents a common complication following inframammary fold lowering in augmentation mammaplasty that mostly occurs in patients with a short distance from the nipple to the inframammary fold or tight breasts. The authors describe a technique that consists of exploiting a cranially based abdominal fat flap that is hinged and rotated upward to correct or prevent this deformity. METHODS: A retrospective study of two groups of patients was conducted. Group A comprised 25 patients who presented with visible double-contour deformity after breast augmentation; group B comprised 22 patients with a constricted lower pole and short distance from the nipple to the inframammary fold undergoing primary augmentation. RESULTS: Of 25 patients in group 1, 22 showed good outcomes. Two patients experienced bilateral and one, unilateral undercorrection of the deformity. One patient had a liponecrotic mass that did not need treatment. No patients in group 2 experienced obvious double-contour deformities. In group 2, one patient showed unilateral excess volume on the medial breast pole and another developed a postoperative hematoma that reabsorbed within 4 weeks. CONCLUSIONS: In many patients, the occurrence of double-contour deformities is linked to the difference in thickness between the area above and below the natural breast fold. The rotated abdominal fat flap increases the thickness of the lower pole in the area between the old and new IMF, which lacked volume, thus treating double-contour deformities in many patients. The same technique can be used to avoid the risk of these deformities when performing primary augmentation in patients with a short distance from the nipple to the inframammary fold or tight breasts.
引用
- Pelle-Ceravolo M, Angelini M, Sanese G, et al. Rotating Abdominal Flap: A New and Simple Technique to Treat and Avoid Lower Pole Contour Deformities in Breast Augmentation. Plast Reconstr Surg. 2023. PMID: 36728166. doi:10.1097/PRS.0000000000010202
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。