文献速递乳房整形与再造

直接植入式胸肌前乳房再造:2年随访时的乳房几何测量与变化

Direct-to-Implant, Prepectoral Breast Reconstruction: Geometric Breast Measurements and Changes at 2-Year Follow-Up.
PubMed 文献 · Plast Reconstr Surg · 2023-05-24

本研究回顾性分析2016年6月至2018年1月由单一术者完成的双侧胸肌前直接植入式乳房再造患者,纳入随访超过2年的72只乳房(38例女性),通过年度标准化正面照片测量乳头至中线、胸骨切迹至乳头、锁骨中点至下极距离。2年后乳头至中线距离平均减少0.41 cm,胸骨切迹至乳头距离平均减少0.62 cm,锁骨中点至下极距离平均上移0.10 cm;接受乳房切除术后放疗的乳房对应变化分别为-0.08、-0.43、-0.56 cm。作者认为观察到的乳房形态变化微小,证明胸肌前直接植入式再造无论是否使用脱细胞真皮基质均可行。

要点

  • 2年随访时乳头至中线距离平均减少0.41 cm,胸骨切迹至乳头距离平均减少0.62 cm。
  • 锁骨中点至下极距离平均上移0.10 cm。
  • 接受乳房切除术后放疗的乳房几何变化分别为-0.08、-0.43、-0.56 cm。

核心结论

  • 作者认为观察到的乳房形态变化微小,证明胸肌前直接植入式再造无论是否使用脱细胞真皮基质均可行。

研究设计与样本

  • 回顾性病历审查,纳入2016年6月至2018年1月由单一术者完成的双侧胸肌前直接植入式乳房再造且随访超过2年的患者,共72只乳房(38例女性)。
  • 通过年度标准化正面照片获取乳头至中线、胸骨切迹至乳头、锁骨中点至下极测量值,并记录患者人口学资料、手术细节和并发症。

主要发现

  • 2年后乳头至中线距离平均减少0.41 cm(范围-2.00至2.97 cm)。
  • 胸骨切迹至乳头距离平均减少0.62 cm(范围-4.98至5.4 cm)。
  • 锁骨中点至下极距离平均上移0.10 cm(范围-6.07至3.6 cm)。
  • 接受乳房切除术后放疗的乳房,上述三项平均变化分别为-0.08、-0.43、-0.56 cm。
  • 56只乳房(78.9%)仅在前方覆盖时使用脱细胞真皮基质;本队列无患者因严重位置不良需再次手术。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Prepectoral breast reconstruction has recently experienced a resurgence in popularity. However, in direct-to-implant (DTI) reconstruction, there is no opportunity for capsular modifications before final implant insertion. Implant pocket and breast shape are thus maintained, initially, solely by the mastectomy skin flaps, and eventually, by attachments of the periprosthetic capsule. The present study aims to quantify changes in breast geometric measurements over time following DTI prepectoral breast reconstruction. METHODS: A retrospective chart review was performed for patients who underwent bilateral prepectoral DTI reconstruction performed by a single surgeon from June of 2016 to January of 2018. Patients followed for more than 2 years were included. Yearly standardized frontal photographs were analyzed, and nipple-to-midline, sternal notch-to-nipple, and midclavicle-to-lower pole measurements were obtained. Patient demographics, operative details, and complications were documented. RESULTS: A total of 72 breasts (38 women) undergoing direct-to-implant, prepectoral breast reconstruction were included in the final analysis. Acellular dermal matrix was used in 56 breasts only (78.9%) for anterior coverage. The average change in nipple-to-midline distance after 2 years decreased by 0.41 cm (range, -2.00 to 2.97 cm), sternal notch-to-nipple distance decreased by 0.62 cm (range, -4.98 to 5.4 cm), and midclavicle-to-lower pole distance decreased 0.10 cm superiorly (range, -6.07 to 3.6 cm). In breasts that underwent postmastectomy radiation therapy, the average changes were -0.08, -0.43, and -0.56 cm, respectively. No patient in this cohort had severe malposition requiring further surgery. CONCLUSIONS: The present study provides insight into geometric breast measurements following prepectoral breast reconstruction at 2-year follow-up. The minimal breast shape changes observed demonstrate the feasibility of prepectoral DTI reconstruction with or without the use of acellular dermal matrix. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.

来源:Plast Reconstr Surg,查看原文。版权归原作者所有。

引用

  1. Safran T, Abi-Rafeh J, Viezel-Mathieu A, et al. Direct-to-Implant, Prepectoral Breast Reconstruction: Geometric Breast Measurements and Changes at 2-Year Follow-Up. Plast Reconstr Surg. 2023. PMID: 36729714. doi:10.1097/PRS.0000000000010095

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。