外科医生实施的彩色多普勒超声腹壁下动脉穿支定位:队列研究与学习曲线评估
这项队列研究纳入20例接受DIEP皮瓣乳房再造的患者(32个皮瓣、59条穿支),比较外科医生实施的彩色多普勒超声(CDU)与CT血管造影(CTA)穿支定位的偏差,并用Joinpoint回归评估CDU学习曲线。CDU平均偏差1.00(0.50-1.12)cm,CTA为0.71(0.50-1.12)cm;学习曲线在第7例患者(约21条定位穿支)后出现拐点,此后两种方法偏差无显著差异(p=0.980)。
要点
- 外科医生实施CDU穿支定位的平均偏差为1.00(0.50-1.12)cm,CTA为0.71(0.50-1.12)cm。
- CDU定位学习曲线在第7例患者(约21条定位穿支)后出现拐点。
- 拐点之后,CDU与CTA的定位偏差无显著差异(p=0.980)。
核心结论
- 外科医生仅需有限次数的检查即可学会CDU腹壁下动脉穿支定位,其准确性类似于CTA定位。
研究设计与样本
- 队列研究纳入20例接受DIEP皮瓣乳房再造的患者,共32个DIEP皮瓣和59条剥离穿支。
- 所有患者术前均接受CTA穿支定位,由放射科医生提取重要穿支的XY坐标。
- 一名对CDU经验极少的外科医生(超声操作者)在不知晓CTA数据的情况下实施CDU穿支定位并提取XY坐标。
- 术中测量剥离穿支的参考坐标,比较两种方法与参考坐标的偏差,并用Joinpoint回归评估CDU定位的学习曲线。
主要发现
- CDU定位坐标与参考坐标的平均偏差为1.00(0.50-1.12)cm,CTA为0.71(0.50-1.12)cm。
- CDU定位学习曲线在第7例患者(约21条定位穿支)后出现拐点。
- 拐点之后,两种方法的偏差无显著差异(p=0.980)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Perforator mapping using diagnostic methods facilitates deep inferior epigastric perforator (DIEP) flap planning. Computed tomographic angiography (CTA) is a well-proven tool for perforator mapping. However, the benefits of color Doppler ultrasonography (CDU) are as follows: 1) CDU involves dynamic real-time examination and 2) does not use radiation. Comparing the accuracies of both methods in a cohort of patients, this study aimed to evaluate the learning curve of surgeon-conducted CDU perforator mapping. METHODS: Twenty patients undergoing DIEP flap breast reconstruction were enrolled in a cohort study. All patients underwent CTA perforator mapping preoperatively. XY coordinates of significant perforators were subtracted by a radiologist. A single surgeon (sonographer) with minimal experience with CDU performed CDU perforator mapping, including XY coordinates subtraction. The sonographer was blinded to the CTA data. The reference coordinates of dissected perforators were measured during surgery. Deviations from reference coordinates for both methods were compared, and CDU mapping learning curve was assessed using Joinpoint Regression. RESULTS: We included 20 women (32 DIEP flaps and 59 dissected perforators). The mean deviation between mapped and reference coordinates was 1.00 (0.50-1.12) cm for CDU and 0.71 (0.50-1.12) cm for CTA. The learning curve of CDU mapping showed the breaking point after the seventh patient (≈ 21 localized perforators). After the breaking point, no significant differences between the deviations of both methods were found (p = 0.980). CONCLUSION: A limited number of examinations were needed for the surgeon to learn CDU DIEA perforator mapping with accuracy similar to that of CTA mapping.
引用
- Bajus A, Kubek T, Dražan L, et al. Surgeon-conducted color Doppler ultrasound deep inferior epigastric artery perforator mapping: A cohort study and learning curve assessment. J Plast Reconstr Aesthet Surg. 2022. PMID: 36512993. doi:10.1016/j.bjps.2022.10.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。