文献速递乳房整形与再造美容整形

合成可吸收补片(GalaFLEX)作为乳房隆乳翻修手术中软组织辅助物的应用

Synthetic Reabsorbable Mesh (GalaFLEX) as Soft Tissue Adjunct in Breast Augmentation Revision Surgery.
PubMed 文献 · Aesthet Surg J · 2023-01-01

本研究回顾性分析了34例既往肌下隆乳后需翻修、将假体腔隙改为腺体下并以上极GalaFLEX补片覆盖的患者,随访6至28个月,未报告轻微或重大并发症,无皱褶/波纹或明显包膜挛缩发生,患者满意度高;作者认为该补片作为辅助装置在复杂翻修病例中改善假体软组织覆盖方面具有安全性。

要点

  • 34例肌下隆乳翻修患者改行腺体下腔隙并以上极GalaFLEX补片覆盖。
  • 随访6至28个月,未报告轻微或重大并发症,无皱褶/波纹或明显包膜挛缩。
  • 术后6个月匿名问卷显示患者满意度高。

核心结论

  • 作者认为,本病例系列的初步结果表明GalaFLEX作为辅助装置在复杂乳房隆乳翻修病例中改善假体软组织覆盖方面具有安全性。

研究设计与样本

  • 回顾性综述,纳入34例既往肌下隆乳后翻修、更换假体并将腔隙改为腺体下、以上极GalaFLEX(Galatea Surgical, BD; Franklin Lakes, NJ)补片覆盖的患者。

主要发现

  • 随访时间最短6个月、最长28个月,期间未报告轻微或重大并发症。
  • 未观察到皱褶/波纹或明显包膜挛缩发生。
  • 术后6个月匿名问卷自我报告显示患者满意度高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A significant number of patients with a previous submuscular breast augmentation require a revision surgical procedure during their long-term follow-up period that involves changing the implant pocket from submuscular to subglandular. Reduced soft tissue thickness represents a major concern, discouraging surgeons from undertaking this approach. OBJECTIVES: The aim of this study was to determine whether a synthetic resorbable mesh used as a supplemental covering device was safe and yielded improved soft tissue thickness and protection against capsular contracture in patients undergoing implant plane shift to subglandular. METHODS: A retrospective review of 34 patients who underwent revision of a previous breast augmentation involving implant change in a subglandular pocket and upper pole GalaFLEX (Galatea Surgical, BD; Franklin Lakes, NJ) mesh coverage was conducted. Onset of minor and major complications was recorded during short- and medium-term follow-up. Patient satisfaction was assessed via an anonymous questionnaire administered 6 months postoperatively. RESULTS: During the follow-up period, which ranged from a minimum of 6 months to a maximum of 28 months, no minor or major complications were reported. In particular, no wrinkling/rippling or significant capsular contracture onset was observed. High levels of patient satisfaction were determined, according to self-reporting questionnaires. CONCLUSIONS: The initial results of this preliminary report from this case series demonstrate the safety of GalaFLEX as a supplemental device in terms of improved soft tissue coverage of the implant for complex revisional cases in breast augmentation.

来源:Aesthet Surg J,查看原文。版权归原作者所有。