解剖型与圆形假体隆乳术后乳房形态学比较:一项前瞻性研究
本研究纳入假体容积小于300 mL的经腋窝双平面隆乳患者,按假体形状分组,术前行三维扫描并于术后6个月复查。解剖型假体组30例与圆形假体组26例在乳房高度/宽度、上极/下极比值及体积丢失率等指标上均无显著差异。作者认为两类假体术后乳房形态差异不明显,体积丢失程度相似。
要点
- 解剖型与圆形假体组术后乳房形态学各比值均无显著差异。
- 两组体积丢失率分别为13.3%±3.9%与13.9%±5%(P=0.489)。
- 术后体积与术前体积及假体体积均呈正相关。
核心结论
- 对于假体容积小于300 mL、经腋窝双平面隆乳的乳房发育不良患者,解剖型与圆形假体术后乳房形态差异不明显。
- 使用这两种形状的假体,体积丢失程度相似。
研究设计与样本
- 前瞻性研究,纳入假体容积小于300 mL的经腋窝双平面隆乳患者并按假体形状分组。
- 解剖型假体组30例,圆形假体组26例。
- 术前及术后6个月行三维扫描,测量乳房高度、宽度、上极高度、下极高度、乳房突出度及上极、下极突出度,并计算相应比值。
- 计算乳房体积、上极体积、下极体积及其比值,并对乳房体积的影响因素行相关与回归分析。
主要发现
- 解剖型与圆形假体平均容积分别为260.5±26.7 mL与267.9±21.7 mL(P=0.192)。
- 两组乳房高度/宽度比值分别为1.39±0.12与1.37±0.19(P=0.582)。
- 两组上极高度/下极高度比值分别为1.35±0.22与1.41±0.25(P=0.160)。
- 两组上极突出度/下极突出度比值分别为0.68±0.19与0.73±0.17(P=0.133)。
- 两组乳房突出度/乳房高度比值分别为0.39±0.08与0.39±0.06(P=0.830);上极体积/下极体积比值分别为0.75±0.11与0.77±0.12(P=0.287)。
关键数值与推荐
- 两组体积丢失率分别为13.3%±3.9%与13.9%±5%(P=0.489)。
- 术后体积与术前体积及假体体积均呈正相关。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The choice of implant shape (anatomic or round) is one of the most critical issues for breast augmentation. Determining whether there are differences in the postoperative breast morphology of the 2 implants is pivotal for surgical planning. This issue has been controversial and lacking in evidence. The aim of this study was to provide reference for implant selection by comparing breast morphology after dual-plane augmentation with anatomic and round implants using 3-dimensional scanning technology. METHODS: Patients with implant volume less than 300 mL who underwent transaxillary dual-plane augmentation were included in this study and were grouped according to implant shape. Three-dimensional scans were performed preoperatively and 6 months postoperatively. Postoperative breast height (BH), breast width (BW), BH of upper pole (BHUP), BH of lower pole (BHLP), breast projection (BP), BP of upper pole (BPUP), and BP of lower pole (BPLP) were measured separately, resulting in corresponding ratios (BH/BW, BHUP/BHLP, BP/BH, BPUP/BPLP). Breast volume, and the volumes of each pole (breast volume of upper pole [BVUP], breast volume of lower pole [BVLP]) and its ratio (BVUP/BVLP) were calculated. Correlation and regression analysis on the influencing factors of breast volume were performed. RESULTS: Thirty patients with anatomic implants and 26 with round implants were enrolled in this study. The mean volumes of anatomic and round implants were 260.5 ± 26.7 and 267.9 ± 21.7 mL (P = 0.192). The ratios of BH/BW in the 2 groups were 1.39 ± 0.12 and 1.37 ± 0.19, respectively (P = 0.582). The BHUP/BHLP values of 2 groups were 1.35 ± 0.22 and 1.41 ± 0.25 (P = 0.160). Two sets of BPUP/BPLP were 0.68 ± 0.19 and 0.73 ± 0.17 (P = 0.133). The ratios of BP/BH in the 2 groups were 0.39 ± 0.08 and 0.39 ± 0.06 (P = 0.830). The BVUP/BVLP ratios for both groups were 0.75 ± 0.11 and 0.77 ± 0.12 (P = 0.287). There was a volume loss rate of 13.3% ± 3.9% and 13.9% ± 5% (P = 0.489). The postoperative volume showed a positive correlation with both the preoperative volume and the implant volume. CONCLUSIONS: For patients with breast dysplasia undergoing transaxillary dual-plane augmentation with anatomic or round implants less than 300 mL, the difference in postoperative breast morphology is not obvious. Using these 2 shapes of implants results in a similar degree of volume loss.