文献速递乳房整形与再造显微修复重建

胸廓内静脉直径——左侧真的更小吗?一项105例双侧游离皮瓣乳房再造患者的研究

Internal mammary vein diameter - Is the left side really smaller? A study of 105 bilateral free flap breast reconstruction patients.
PubMed 文献 · J Plast Reconstr Aesthet Surg · 2022-10-17

该研究回顾105例双侧游离皮瓣乳房再造患者,以静脉耦合器尺寸比较左右胸廓内静脉直径。右侧平均耦合器尺寸2.64 mm(SD 0.35),左侧2.48 mm(SD 0.32),配对t检验P=0.00032,差异有统计学意义。作者结论:右侧胸廓内静脉直径大于左侧,但左侧皮瓣无静脉淤血或皮瓣失败,胸廓内静脉仍是安全的受区静脉选择。

要点

  • 右侧胸廓内静脉耦合器平均2.64 mm(SD 0.35),左侧2.48 mm(SD 0.32),配对t检验P=0.00032。
  • 右侧胸廓内静脉直径大于左侧,差异有统计学意义。
  • 左侧皮瓣未出现静脉淤血或皮瓣失败,胸廓内静脉仍是安全的受区静脉选择。

核心结论

  • 作者确认右侧胸廓内静脉直径大于左侧,并证明该差异在所用耦合器尺寸上具有可记录的实际差异。
  • 尽管存在该差异,左侧皮瓣未出现静脉淤血或皮瓣失败,提示胸廓内静脉仍是安全的受区静脉选择。

研究设计与样本

  • 研究检索本院游离皮瓣数据库,纳入2018年10月至2021年8月间行双侧乳房再造且使用胸廓内血管的患者。
  • 共纳入105例双侧乳房再造患者,平均年龄48.4岁,采用配对t检验进行统计分析。

主要发现

  • 右侧所用静脉耦合器平均尺寸为2.64 mm(SD 0.35),左侧胸廓内静脉耦合器平均尺寸为2.48 mm(SD 0.32)。
  • 配对t检验比较队列中左右胸廓内静脉尺寸的P值为0.00032,显示差异有统计学意义。

关键数值与推荐

  • 右侧胸廓内静脉耦合器平均2.64 mm(SD 0.35)vs 左侧2.48 mm(SD 0.32),配对t检验P=0.00032。

临床怎么用

  • 作者结论认为胸廓内静脉仍是安全的受区静脉选择,左侧皮瓣未出现静脉淤血或皮瓣失败。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Autologous free flap breast reconstruction is currently considered as the gold standard in breast reconstruction as it provides a durable, natural result. The internal mammary vessels are the most commonly used recipient vessels in free flap breast reconstruction, and anecdotally we have often observed that the left internal mammary vein (IMV) appears smaller than the right IMV. The aim of this study is to compare the diameters of the right and left IMVs by recording the size of the venous coupler used on each side in a large series of bilateral free flap breast reconstructions. METHODS: We searched our free flap database for patients who had breast reconstruction between October 2018 and August 2021. Inclusion criteria for this study were bilateral breast reconstruction patients, where the internal mammary vessels were used. We used a paired t-test for statistical analysis of the data. RESULTS: A total of 105 patients who had bilateral breast reconstruction were included in this study. Their mean age was 48.4 years. The mean venous coupler size used on the right was 2.64 mm (SD 0.35), whilst the mean left IMV coupler size was 2.48 (SD 0.32). Using a paired t-test, the p value for the comparison of the right and left IMV size in the cohort was 0.00032, demonstrating a statistically significant difference. CONCLUSION: We have confirmed that the right IMV is larger in diameter than the left side, and demonstrated that this translates into a recordable practical difference in the coupler size used. Despite this, we experienced no venous congestion or flap failures in our left-sided flaps, indicating that the IMVs remain a safe choice of recipient vein.

来源:J Plast Reconstr Aesthet Surg,查看原文。版权归原作者所有。

引用

  1. Hagiga A, Sepehripour S, Molina A, et al. Internal mammary vein diameter - Is the left side really smaller? A study of 105 bilateral free flap breast reconstruction patients. J Plast Reconstr Aesthet Surg. 2022. PMID: 36512994. doi:10.1016/j.bjps.2022.10.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。