我们使用圆形纳米表面Ergonomix假体进行乳房再造的经验:单中心回顾性研究
该单中心回顾性研究回顾了2017年6月至2020年12月间212例患者(321侧乳房)使用圆形纳米表面Ergonomix假体进行乳房再造的病历,随访至少12个月。主要并发症发生于21侧乳房(6.5%),再造失败1例(0.3%),包膜挛缩率0.9%且仅见于放疗乳房,患者满意度高。
要点
- 主要并发症发生于21侧乳房(6.5%),其中20侧行翻修手术,再造失败1例(0.3%)。
- 即刻再造、放疗乳房和吸烟者并发症发生率更高(P分别为0.009、0.02、0.022)。
- 波纹征在胸肌前平面较胸肌后更常见(9% vs 1.2%,P=0.001),包膜挛缩率0.9%且仅见于放疗乳房。
核心结论
- 使用圆形纳米表面Ergonomix假体进行乳房再造并发症率低且患者满意度高。
- 从粗纹理假体向纳米表面假体的转变具有手术操作意义,需要学习曲线和手术调整。
研究设计与样本
- 单中心回顾性研究,回顾2017年6月至2020年12月间212例患者(321侧乳房)使用圆形纳米表面Ergonomix假体进行乳房再造的病历,术后随访至少12个月。
主要发现
- 211例患者中75.4%因癌症手术,24.6%接受预防性手术。
- 主要并发症发生于21侧乳房(6.5%),其中20侧行翻修手术,再造失败1例(0.3%),轻微并发症11侧乳房(3.4%)。
- 即刻乳房再造、放疗乳房和吸烟者并发症发生率更高(P分别为0.009、0.02、0.022)。
- 波纹征在胸肌前平面较胸肌后更常见(9% vs 1.2%,P=0.001)。
- 包膜挛缩率0.9%且仅发生于放疗乳房;假体移位(下移和侧移)发生于6.5%的乳房,假体移位与假体平面无关联。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Round nano-surface Ergonomix (Motiva, Establishment Labs; Alajuela, Costa Rica) implants were developed to address concerns regarding capsular contracture and textured anatomical breasts implants. OBJECTIVES: The authors describe their early experience with Ergonomix implants in breast reconstruction. METHODS: The authors retrospectively reviewed the charts of 212 patients (321 breasts) who underwent breast reconstruction employing round nano-surface Ergonomix implants between June 2017 and December 2020. Patients were followed for at least 12 months postoperatively. Demographics, surgical data, and postoperative surgical outcomes were recorded. Postoperative physical well-being and satisfaction with the breasts and implant were evaluated with Breast-Q questionnaires. RESULTS: Of 211 patients, 75.4% had surgery due to cancer, and 24.6% underwent prophylactic surgery. Major complications occurred in 21 breasts (6.5%), of which 20 underwent revision operations. Reconstruction failed in 1 case (0.3%). Eleven breasts (3.4%) had minor complications. Immediate breast reconstruction, irradiated breasts, and smokers had higher rates of complications (P = 0.009, 0.02, 0.022, respectively). Rippling was more common in the pre-pectoral implant plane compared with sub-pectoral reconstruction (9% vs 1.2%, P = 0.001). Capsular contracture rate was 0.9% and occurred only in irradiated breasts. Implant malposition (inferiorly and laterally) occurred in 6.5% of the breasts, with no association between implant malposition and implant plane. Early follow-up demonstrated high patient satisfaction with the implant and breasts, and high scores in terms of patients' physical well-being. CONCLUSIONS: Breast reconstruction employing the round nano-surface Ergonomix implant yielded low complication rates and high patient satisfaction. The transition from macro-textured to nano-surface implants has operative implications requiring a learning curve and surgical adjustments.
引用
- Adelson D, Singolda R, Haran O, et al. Our Experience Using Round Nano-Surface Ergonomix Implants for Breast Reconstruction: A Single-Center Retrospective Study. Aesthet Surg J. 2023. PMID: 36253945. doi:10.1093/asj/sjac264
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。