本研究探讨负压伤口治疗联合滴注与停留时间(NPWTi-d)中泡沫洗脱液的细菌定植,以判断治疗期间伤口是否可能再污染。采用常规培养与分子生物学方法检测伤口床、泡沫和洗脱液。结果显示泡沫与洗脱液始终存在细菌污染,NPWTi-d较NPWT显著减少病原菌种数。

要点

  • 泡沫和洗脱液始终存在细菌污染。
  • NPWTi-d较NPWT显著减少病原菌种数。
  • 常规培养仅检出53.8%病原菌,联合FISHseq检出96.2%。

核心结论

  • NPWTi-d期间泡沫中的细菌负载被冲回伤口。
  • 当病原菌鉴定和非浮游细菌生长检测对患者治疗特别重要时,应在常规培养方法之外加用FISHseq。

研究设计与样本

  • 研究比较NPWT(n=15)与含抗菌剂滴注的NPWTi-d(n=15),在治疗前(时间点1)和治疗后(中位3.0天;时间点2)检测伤口床、泡沫和洗脱液。
  • 共纳入22处急性伤口和8处慢性伤口;中位年龄51岁(范围24至91岁);26名男性。
  • 检测方法包括常规培养、荧光原位杂交(FISH)、聚合酶链反应和FISH测序(FISHseq)。

主要发现

  • 时间点2时,洗脱液中可识别的病原菌有94.9%(37/39)也在伤口床中检出。
  • 泡沫和洗脱液始终存在细菌污染。
  • NPWTi-d较NPWT显著减少病原菌种数(NPWTi-d时间点1 vs 时间点2:P=0.026;NPWT时间点1 vs 时间点2:无显著差异)。
  • 时间点2伤口床样本常规培养仅检出52种病原菌中的28种(53.8%),而联合检测伤口床、泡沫、洗脱液并加用FISHseq检出52种中的50种(96.2%)。
  • FISHseq在时间点2检出1处伤口有生物膜、10处伤口有微菌落。

临床怎么用

  • 作者认为,当病原菌鉴定和非浮游细菌生长检测对患者治疗特别重要时,应在常规培养方法之外加用FISHseq。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study investigated bacterial colonization of the foam eluate after negative-pressure wound therapy (NPWT) with instillation and dwell time (NPWTi-d) to obtain an indication of possible recontamination of the wound during NPWTi-d. To detect bacterial colonization and the extent of planktonic and nonplanktonic bioburden as comprehensively as possible, routine culture and molecular biology methods were used. METHODS: Before (time point 1) and after (median 3.0 days; time point 2) NPWT ( n = 15) and NPWTi-d with antiseptic installation ( n = 15), wound bed [22 acute, eight chronic wounds; median age, 51 years (range, 24 to 91); 26 men], foam, and eluate were examined by routine culture methods and fluorescence in situ hybridization (FISH), polymerase chain reaction, and FISH sequencing (FISHseq). RESULTS: At time point 2, 94.9% (37 of 39) of the pathogens identifiable in the eluate were also detected in the wound bed. Foam and eluate were always bacterially contaminated. NPWTi-d resulted in a significant reduction in the number of pathogen species compared with NPWT (NPWTi-d, time point 1 versus time point 2: P = 0.026; NPWT, time point 1 versus time point 2: not significant). Routine culture of wound bed samples at time point 2 identified only 28 of 52 (53.8%) of the pathogens, whereas examination of wound bed, foam, and eluate and additional FISHseq use detected 50 of 52 (96.2%) of the bacterial species. FISHseq identified biofilm in one and microcolonies in 10 wounds (time point 2). CONCLUSIONS: The bacterial load of the foam is flushed back into the wound during NPWTi-d. FISHseq should be used in addition to the routine culture method when pathogen identification and detection of nonplanktonic bacterial growth is particularly important for the patient's therapy. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, V.