异丙酚与氯胺酮程序性镇静方案在儿童烧伤反复换药中的安全性与有效性:10年单中心经验
该研究回顾性分析了2011至2021年间104例烧伤患儿(年龄45至135个月,中位烧伤总体表面积11.5%)接受378次以异丙酚和氯胺酮为基础的程序性镇静。64次(17%)发生轻微不良事件,其中50次(13%)为一过性低氧血症,12次(3%)为上气道梗阻,2次(0.5%)为低血压,无严重不良事件。35例(33.6%)患者接受重复镇静,异丙酚剂量或不良事件无统计学显著变化。
要点
- 104例患儿共378次换药镇静,中位异丙酚总剂量7 mg/kg(IQR 5.3,9.2)。
- 轻微不良事件64次(17%),一过性低氧血症最常见(50次,13%),无严重不良事件。
- 35例(33.6%)重复镇静,异丙酚剂量及不良事件无统计学显著变化。
核心结论
- 儿童可在住院期间反复烧伤换药时接受有效镇静。
- 鉴于患者人群高风险,该操作应在训练有素人员的严密监护下进行。
研究设计与样本
- 回顾性病历审查,纳入2011年至2021年接受住院烧伤换药镇静的儿科患者。
- 共104例患者,年龄45至135个月,中位烧伤总体表面积11.5%(四分位距4.0,25.0)。
- 共实施378次以异丙酚和氯胺酮为基础的程序性镇静。
主要发现
- 异丙酚中位总剂量为7 mg/kg(四分位距5.3,9.2)。
- 64次镇静(17%)发生轻微不良事件:一过性低氧血症50次(13%)、上气道梗阻12次(3%)、低血压2次(0.5%)。
- 无严重不良事件发生。
- 低氧血症与年龄、体重、性别、烧伤总体表面积或异丙酚总剂量无关。
- 35例患者(33.6%)接受重复镇静,重复镇静时异丙酚剂量或不良事件无统计学显著变化。
临床怎么用
- 作者认为儿童可在住院期间反复烧伤换药时接受有效镇静。
- 作者指出鉴于患者人群高风险,该操作应在训练有素人员的严密监护下进行。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
It is crucial to provide an adequate level of sedation and analgesia during burn dressing changes in the pediatric population due to the amount of pain and anxiety patients experience during the procedure. To evaluate the safety and efficacy of an intensivist-based deep sedation regimen using a combination of propofol and ketamine to provide procedural sedation to pediatric burn patients. This is a retrospective chart review of pediatric patients who underwent inpatient burn wound dressing changes from 2011 through 2021. Demographic and clinical data, including age, length of the procedure, recovery time, medication doses, and adverse events, were collected. A total of 104 patients aged between 45 and 135 months with a median total burn body surface area (TBSA) of 11.5 percent (interquartile range [IQR] 4.0, 25.0) underwent 378 procedural sedation encounters with propofol- and ketamine-based sedation. The median total dose of propofol was 7 mg/kg (IRQ 5.3, 9.2). Of these sedations, 64 (17 percent) had minor adverse events, of which 50 (13 percent) were transient hypoxemia, 12 (3 percent) were upper airway obstruction, and 2 (0.5 percent) were hypotension. There were no serious adverse events. Hypoxemia was not related to age, weight, gender, burn TBSA, or total dose of propofol. There were 35 (33.6 percent) patients who had repetitive sedation encounters with no statistically significant changes in propofol dose or adverse events with the repeated encounters. Children can be effectively sedated for repetitive inpatient burn dressing changes. Given the high-risk patient populations, this procedure should be performed under the vigilance of highly trained providers.
引用
- Yabrodi M, Shieh Yu J, Slaven JE, et al. Safety and Efficacy of Propofol- and Ketamine-Based Procedural Sedation Regimen in Pediatric Patients During Burn Repetitive Dressing Change: 10 Years Single Center Experience. J Burn Care Res. 2023. PMID: 36194090. doi:10.1093/jbcr/irac144
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。