用于烧伤实验研究的自动化高通量平台——体外与离体研究
研究建立自动化高通量烧伤平台(HTBP),通过96针铝制加热块与高精度致动器控制烧伤温度、接触时间和压力,在体外细胞与离体猪皮中验证其可产生可重复的局部热损伤,高温和长接触时间降低细胞活力并增大烧伤面积。
要点
- HTBP可精确控制烧伤温度、接触时间和压力,支持96孔板与皮肤样本的高通量烧伤实验。
- 在人脐静脉内皮细胞和NIH-3T3成纤维细胞中,更高温度和更长接触时间降低细胞活力并增大烧伤面积。
- 在细胞单层中,75 °C下仅200毫秒暴露即可造成严重烧伤创面。
核心结论
- HTBP可作为在严格受控条件下以高通量方式开展轻度和重度烧伤体外与离体研究的重要工具。
研究设计与样本
- 研究建立自动化高通量烧伤平台(HTBP),由96针铝制加热块和高分辨率致动器组成,致动器将96孔细胞培养板和皮肤样本压向加热块针体。
主要发现
- 在人脐静脉内皮细胞和NIH-3T3成纤维细胞中,更高温度和更长接触时间降低细胞活力并增大烧伤面积。
- 在细胞单层中,75 °C下仅200毫秒暴露即可造成严重烧伤创面。
- 在离体猪皮中,100 °C下500毫秒暴露后组织学切片可见真皮变色。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The use of in-vitro and ex-vivo models for the study of burn wound injuries is encouraged to reduce the animal burden in experimental burn research. However, few existing platforms enable the production of reproducible, locally confined thermal injuries at short durations in a high-throughput manner for both in-vitro and ex-vivo models. To address this gap, we established an automated high-throughput burn platform (HTBP) that provided accurate control over burn temperature, exposure time, and pressure application. This platform was built by fabricating an aluminum heat block with 96 pins and positioning a high-resolution actuator below the block. By activating the actuator, 96-well cell culture plates and skin samples were pressed against the heat block's pins. We demonstrated the applicability of the HTBP for studying in-vitro burn injuries by investigating the effects of burn temperature and contact duration on cell viability and migration in human umbilical vein endothelial cells and NIH-3T3 fibroblasts. We showed that higher temperatures and a longer contact duration decreased cellular viability and increased the area of the burn. Moreover, we found that even a short exposure time of 200 msec caused a severe burn wound at 75 °C in a cell monolayer. In addition, we used the HTBP to generate burn injuries at different burn durations in ex-vivo porcine skin and showed that dermis discoloration was present in histologic sections after exposure to 100 °C for a short duration of 500 msec. Our work demonstrates that the HTBP can constitute an important tool for both in-vitro and ex-vivo research of mild and severe burn injuries in a tightly controlled setting and high-throughput manner.
引用
- Melnikov N, Kobel P, Detinis T, et al. An automated high-throughput platform for experimental study of burn injuries - in vitro and ex vivo. Burns. 2022. PMID: 36195492. doi:10.1016/j.burns.2022.08.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。