文献速递美容整形瘢痕与激光

可吸收缝线锚技术:睑袋整形术后下睑外翻的治疗方法

Absorbable Suture Anchor Technique: A Method for Postblepharoplasty Lower Eyelid Ectropion Treatment.
PubMed 文献 · Ann Plast Surg · 2022-08-18

本文介绍可吸收缝线锚技术治疗下睑整形术后下睑外翻。2017年12月至2021年1月由单一术者治疗47例(64眼),平均年龄43岁(范围27–61岁)。总体成功率98%,1例(2.1%)出现下睑组织感染,经引流和换药控制。

要点

  • 可吸收缝线锚技术治疗下睑整形术后下睑外翻总体成功率98%。
  • Ⅰ–Ⅲ级及Ⅴ级外翻成功率100%,Ⅳ级为95%。
  • 1例(2.1%)出现下睑组织感染,经引流和换药控制。

核心结论

  • 可吸收缝线锚技术是矫正睑袋整形术后下睑外翻的有效、微创且安全的方法。

研究设计与样本

  • 单术者病例系列,2017年12月至2021年1月纳入47例(64眼)下睑整形术后下睑外翻患者,平均年龄43岁(范围27–61岁)。
  • 所有患者先松解中层粘连和瘢痕组织,再用可吸收缝线锚技术悬吊下睑;9例因重度下睑松弛另行眼睑楔形切除。
  • 术前采用Ectropion Grading Scale和牵拉试验评估,手术成功以Ectropion Grading Scale和临床检查定义。

主要发现

  • 46例(97.9%)眼睑外翻得到充分矫正,美学与功能均明显改善;1例(2.1%)出现并发症,经引流和换药后控制,原有症状也大部分缓解。
  • Ⅰ–Ⅲ级和Ⅴ级外翻成功率100%,Ⅳ级成功率95%,总体成功率98%。
  • 首次重建手术患者成功率100%,接受1次或以上重建手术患者成功率90%。
  • 1例(1眼)发生下睑组织感染,经引流和换药控制,原有症状大部分缓解。

临床怎么用

  • 作者认为可吸收缝线锚技术是矫正睑袋整形术后下睑外翻的有效、微创且安全的方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Postblepharoplasty ectropion is a very complex problem to deal with because its relevance is far to be only a functional complaint. Therefore, the best surgical approach requires both aesthetic and functional consideration. Here, we introduce the absorbable suture anchor technique, which can meet both needs, and its surgical procedure is simple and effective and has excellent stability for long-term results. This series included only ectropion patients caused by lower eyelid blepharoplasty, with or without receiving revision surgery. Forty-seven cases (64 eyes) were treated by a single surgeon through this method. Forty-six patients (97.9%) displayed adequate correction of the eyelid ectropion and a marked degree of improvement both in aesthetic terms and with regard to the functional disorders reported. One patient (2.1%) presented complications but brought under control after drainage and dressing change. His previous symptoms were also largely relieved. Absorbable suture anchor technique is an effective, minimally invasive, and safe method to correct postblepharoplasty ectropion. In this study, we describe an absorbable suture anchor technique and its outcomes in the repair of ectropion caused by lower eyelid blepharoplasty. From December 2017 to January 2021, 47 patients (64 eyes) with lower eyelid ectropion were treated with this technique (mean age, 43 years; age range, 27–61 years). This series included only patients with ectropion caused by lower eyelid blepharoplasty, with or without revision surgery. Patients were assessed with the Ectropion Grading Scale and distraction test preoperatively. All patients first underwent the release of middle lamellar adhesions and scar tissue, and then, the absorbable suture anchor technique was used to suspend the lower eyelid; 9 patients also underwent eyelid wedge excision because of severe lower eyelid laxity. The success rate was 100% for grade I–III and V ectropion and 95% for grade IV. The overall success rate was 98%. In terms of correction iterations, the success rate 100% for patients undergoing their first reconstructive surgery and 90% for patients who had 1 or more reconstructive surgeries. Surgical success was defined in terms of the Ectropion Grading Scale and clinical examination. One patient (1 eye) developed a lower eyelid tissue infection that was controlled with drainage and dressing changes; his previous symptoms were largely relieved. The absorbable suture anchor technique is an effective, minimally invasive, and safe method for correcting postblepharoplasty lower eyelid ectropion.

来源:Ann Plast Surg,查看原文。版权归原作者所有。

引用

  1. Li H, Zhao Y. Absorbable Suture Anchor Technique: A Method for Postblepharoplasty Lower Eyelid Ectropion Treatment. Ann Plast Surg. 2022. PMID: 36155941. doi:10.1097/SAP.0000000000003275

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。