自体脂肪移植中不同处理技术临床结局的前瞻性随机比较
该前瞻性随机研究比较了三种脂肪移植物制备方法(主动冲洗过滤系统、被动冲洗过滤系统与离心法)的临床结局,共纳入46例患者。结果显示各组在早期并发症、脂肪坏死及再次移植率上无显著差异,但曾接受保乳治疗的患者脂肪坏死风险显著更高,且与处理技术无关。
要点
- 三组脂肪坏死概率无显著差异:主动过滤15% vs 被动过滤14.3% vs 离心8%(p=0.72)。
- 保乳术后患者脂肪坏死率显著更高(60%,p=0.011),与处理技术无关。
- 轮廓不规则与再次移植率在三组间均无显著差异。
核心结论
- 三种脂肪处理技术在早期并发症、脂肪坏死及再次移植率方面无显著差异。
- 曾接受保乳治疗的患者脂肪坏死风险显著更高,且与处理技术无关。
研究设计与样本
- 前瞻性随机研究,共纳入46例患者,分为主动冲洗过滤系统组15例、被动冲洗过滤系统组15例和离心法组16例。
- 患者平均年龄54岁,平均体重指数28.6 kg/m²,平均随访时长16.9±4个月。
主要发现
- 总体并发症发生率为12.1%。
- 脂肪坏死概率在三组间无差异:主动过滤组15% vs 被动过滤组14.3% vs 离心组8%(p=0.72)。
- 保乳术后患者脂肪坏死率最高(60%,p=0.011)。
- 轮廓不规则率在三组间无显著差异:主动过滤组40% vs 被动过滤组38% vs 离心组36%(p=0.96)。
- 再次移植率在三组间无显著差异:主动过滤组40% vs 被动过滤组24% vs 离心组32%(p=0.34)。
关键数值与推荐
- 证据等级:治疗性,II级。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Autologous fat grafting is a useful tool in breast reconstruction. The authors have previously demonstrated a difference in the rate of processing adipose grafts in a randomized time and motion clinical trial. The purpose of this study was to compare clinical outcomes in commonly used grafting systems. METHODS: Three methods to prepare adipose grafts were compared: a passive washing filtration system (Puregraft system), an active washing filtration system (Revolve system), and centrifugation (Coleman technique). Postoperative complications, rates of fat necrosis, revision procedures, and additional imaging were recorded. RESULTS: Forty-six patients were included in the prospective, randomized study (15 active filtration, 15 passive filtration, and 16 centrifugation). Their mean age was 54 years and mean body mass index was 28.6 kg/m 2 . The mean length of follow-up was 16.9 ± 4 months. The overall complication rate was 12.1 percent. The probability of fat necrosis was no different between the groups (active filtration, 15 percent versus passive filtration, 14.3 percent] versus centrifugation, 8 percent; p = 0.72). Fat necrosis was highest in patients with breast conservation before grafting (60 percent; p = 0.011). There was no significant difference in contour irregularity (active filtration, 40 percent versus passive filtration, 38 percent versus centrifugation, 36 percent; p = 0.96) or additional grafting (active filtration, 40 percent versus passive filtration, 24 percent versus centrifugation, 32 percent; p = 0.34). CONCLUSIONS: This is the first prospective, randomized study to compare clinical outcomes of adipose graft preparation. There was no significant difference in early complications, fat necrosis, or rates of additional grafting among the study groups. There was significantly higher risk of fat necrosis in patients with previous breast conservation treatment regardless of processing technique. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, II.
引用
- Hanson SE, Garvey PB, Chang EI, et al. A Prospective, Randomized Comparison of Clinical Outcomes with Different Processing Techniques in Autologous Fat Grafting. Plast Reconstr Surg. 2022. PMID: 35994347. doi:10.1097/PRS.0000000000009613
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。