超薄股深动脉穿支皮瓣用于四肢重建的临床意义
作者描述其采用薄及超薄股深动脉穿支皮瓣进行四肢重建的方法与经验,术前联合CT血管造影、彩色多普勒和手持多普勒定位穿支,连续10例患者均使用单一优势穿支,平均皮瓣厚度0.7±0.2 cm,平均血管蒂长6.8±1.2 cm,术前CT血管造影与术中测量的近远端距离平均差1.2±0.6 cm。
要点
- 薄及超薄股深动脉穿支皮瓣为四肢重建提供新选择,供区隐蔽、穿支口径大、血管蒂长、穿支解剖直接。
- 连续10例四肢创面(上肢3例、下肢7例)均采用单一优势穿支完成重建。
- 术中优势穿支近远端距离测量与术前CT血管造影测量之差在全部病例中均不超过2 cm。
核心结论
- 薄及超薄股深动脉穿支皮瓣为四肢重建提供新的重建选择,尤其适合用于四肢。
研究设计与样本
- 作者描述其采用薄及超薄股深动脉穿支皮瓣进行四肢重建的方法与经验,连续纳入10例患者,证据等级为治疗性IV级。
- 术前通过CT血管造影、彩色多普勒和手持多普勒定位穿支,术中均使用单一优势穿支。
主要发现
- 患者平均年龄41.2±21.3岁,皮瓣用于覆盖上肢创面3例和下肢创面7例。
- 平均皮瓣厚度0.7±0.2 cm,平均皮瓣动脉直径16±3 mm,平均皮瓣静脉直径21±6 mm,平均血管蒂长度6.8±1.2 cm。
- 每例患者术中实际测量的近远端距离与术前CT血管造影测量值之间的平均差为1.2±0.6 cm。
- 全部病例中术中测量的优势穿支近远端距离与术前CT血管造影测量值之差均在2 cm以内。
临床怎么用
- 作者描述其采用薄及超薄股深动脉穿支皮瓣进行四肢重建,术前联合CT血管造影、彩色多普勒和手持多普勒定位穿支,术中采用单一优势穿支。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
SUMMARY: The profunda artery perforator flap has numerous advantages. For coverage of extremity wounds, however, traditional subfascial harvest results in a thick flap, which routinely requires secondary thinning. The author describes his approach and experience with thin and superthin profunda artery perforator flaps for extremity reconstruction. With preoperative perforator localization via computed tomography angiogram, color Doppler, and handheld Doppler, the author used a single dominant perforator for extremity reconstruction in 10 consecutive patients. The mean age of patients who had a thin or superthin profunda artery perforator flap for extremity reconstruction was 41.2 ± 21.3 years. Flaps were used to cover wounds in the upper ( n = 3) and lower ( n = 7) extremities. Mean flap thickness was 0.7 ± 0.2 cm. Mean flap artery diameter was 16 ± 3 mm; mean flap vein diameter was 21 ± 6 mm. Mean pedicle length was 6.8 ± 1.2 cm. The difference between the actual measured intraoperative proximal-distal distance and the preoperative computed tomography angiogram measurement for each patient was calculated, with a mean difference of 1.2 ± 0.6 cm. Advantages of the profunda artery perforator flap include a concealed donor site, large perforator caliber, long pedicle length, and a straightforward perforator dissection. Intraoperative measurement of the proximal-distal distance of the dominant perforator fell within 2 cm of the preoperative computed tomography angiogram measurement in all cases. The thin and superthin profunda artery perforator flaps provide new reconstructive options, particularly suited for use in the extremities. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.
引用
- Chim H. The Superthin Profunda Artery Perforator Flap for Extremity Reconstruction: Clinical Implications. Plast Reconstr Surg. 2022. PMID: 35939645. doi:10.1097/PRS.0000000000009562
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。